JBRB ECOWATT® PR - JBRB ECOWATT® PR SIGFOX

Regulated C4 extraction boxes

Direct drive - Backward - ECM < 9200 m3/h

JBRB ECOWATT® PR HL SIGFOX 22 View larger

JBRB ECOWATT® PR - JBRB ECOWATT® PR SIGFOX

Regulated C4 extraction boxes


Direct drive - Backward - ECM < 9200 m3/h

PIC-ERP-conforme-01.jpg ErP Compliant - Erp Compliant
UVNR - Variable EC motor
PIC-Isolation-acoustique-01.jpg PIC-ATEC-HYGRO-CSTB-01.jpg Moteur ECM PIC-Isolation-acoustique-01.jpg
Maintenance facilitée GTC Modbus Sigfox OPTAIR RT Conso

  • Low consumption ECM motor out of the air flow
  • High performance reaction wheel
  • COP, CAV, VAV operation
  • Communicating Modbus, SIGFOX
  • Compliance Hygro technical advice
  • Multiple installation configurations
  • Easy maintenance
  • Single phase or three phase

Application

Air extraction.
Indoor or outdoor installation.
400 ° C 1 / 2h category C4 approved.
CMV in collective housing and tertiary premises.
Air intake in tertiary premises.
Extraction in professional kitchens.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow rates from 100 to 9200 m3/ h.
10 sizes: 04/06/10/22/30/38/48/70/82/92.
JBRB ECOWATT® PR: Modbus communicator.
JBRB ECOWATT® PR SIGFOX: Sigfox communicator.
Available configurations:
  • L: online.
  • M: modular, supplied with a cap for 1 or 2 90 ° aspirations.
  • D: double suction at 180 °.
Horizontal or vertical discharge version.
Insulated version: acoustic insulation by 25 mm glass wool (A2-s1, d0 (M0) fire classification) in double skin panels.


Options - CORROSION PROTECTION


Construction
  • Z275 Galvanized sheet steel box fitted with 4 fixing brackets (size 04 to 38) or 2 transerval omega (sizes 48 to 92).
  • Lifting by 2 steel legs or by slinging through the omegas.
  • Connection nozzle with class D sealing gaskets. Vertical discharge version supplied without connection nozzle (flat nozzle with PAPV seal to be fitted as an option with self-drilling screws).
  • Direct coupling.
  • INTZ: mounted / wired padlockable proximity switch.
  • High performance galvanized steel reaction turbine.
  • Lid equipped with 2 or 4 handles, removable without tools to ensure easy access to the interior of the box for cleaning.
  • Horizontal or vertical discharge version.
  • IS version: Acoustic insulation by 25 mm M0 glass wool in double skin panels.
  • Corrosion resistance treatment option: contact us.
Motorization
  • Direct current motor (ECM) out of air flow:
    • 04 to 22: IP44 class B single phase 230V, 50Hz.
    • 30, 38, 48, 70, 82: IP54, class F, single phase 230V, 50Hz.
    • 30, 38, 48, 70, 92: IP 54, class F, three-phase 400V, 50Hz.
  • Thermal protection managed by electronics and approved for C4 operation.
Regulation - RMEC
  • Operation in COP (constant pressure), VAV (variable flow) or CAV (constant flow).
  • Control box, IP55, factory fitted and wired.
  • Backlit LCD display, with function keys on the front, optional remote control.
  • Clear display of the measurement (pressure, flow) and the setpoint.
  • Integrated ventilation fault signaling: dry contact available on the RMEC terminal block (breaking capacity at 230Vac: 3A resistive).
Communication
JBRB ECOWATT® PR
  • ModBus RTU communication as standard.
JBRB ECOWATT® PR SIGFOX: see IoT connected products
  • SIGFOX network, very low speed and very long range cellular wireless network with national coverage.
  • Allows the supervision of collective or tertiary VMC installation.
  • Economical alternative technology to wired / 3G solutions for surveillance or remote reading.
  • Additional card integrated into the RMEC for uploading data on the SIGFOX radio network:
    • average, minimum and maximum pressure of the installation,
    • average, minimum and maximum flow of the installation,
    • signal sent in the event of a power failure,
    • signal sent in the event of a power return,
    • alarm on pressure threshold and minimum flow rate.

Fan selection C4 - 400 ° C 1 / 2H
JBRB ECOWATT® PR - PR SIGFOX 04 / 06 / 10 / 22 / 30 / 38 - L / M
Horizontal discharge

 

--- Available only on the "M" modular version

Model

A**

A

B

B'

C* and **

C***

D1

E

F

G

H

I

J

Weight (kg)

JBRB ECOWATT® PR - PR SIGFOX 04

627

648

523

533

320

321

160

568

502

157

175

157

161

22

JBRB ECOWATT® PR - PR SIGFOX 06

627

648

523

533

320

321

200

568

502

157

175

157

161

22

JBRB ECOWATT® PR - PR SIGFOX 10

627

648

566

583

421

440

250

569

544

207

185

207

186

26

JBRB ECOWATT® PR - PR SIGFOX 22

767

789

683

701

511

530

355

709

661

252

237

252

239

45

JBRB ECOWATT® PR - PR SIGFOX 30

1019

1019

820

873

568

585

400

892

797

267

271

267

271

64

JBRB ECOWATT® PR - PR SIGFOX 38

1153

1153

938

971

631

656

500

1036

907

306

331

306

331

78

* IS version: +27 mm ** JBRB ECOWATT PR version only ***JBRB ECOWATT PR SIGFOX, IS version: +10 mm

JBRB ECOWATT® PR - PR SIGFOX 48 / 70 / 82 / 92 - L / M
Horizontal discharge



--- Available only on the "M" modular version

Model

A

B

B'

C* and **

C***

D1

E

F

G

H

I

J

Weight (kg)

JBRB ECOWATT® PR - PR SIGFOX 48

1165

985

1065

800

819

560

700

918

433

330

433

330

107

JBRB ECOWATT® PR - PR SIGFOX 70

1280

1030

1100

880

900

630

815

970

473

365

473

365

121

JBRB ECOWATT® PR - PR SIGFOX 82

1404

1100

1175

970

988

710

846

1032

518

405

518

405

170

JBRB ECOWATT® PR - PR SIGFOX 92

1404

1100

1175

970

988

710

846

1032

518

405

518

405

170

* version IS: +27 mm ** version JBRB ECOWATT PR uniquement ***JBRB ECOWATT PR SIGFOX, version IS : +10 mm

JBRB ECOWATT® PR - PR SIGFOX 04 / 06 / 10 / 22 / 30 / 38 - L / M
Vertical discharge



--- Available only on the "M" modular version

Model

A**

A

B

B'

C* and **

C***

D1

E

F

G

H

I

J

Weight (kg)

JBRB ECOWATT® PR - PR SIGFOX 04

609

648

523

533

320

321

160

568

502

157

175

130

165

22

JBRB ECOWATT® PR - PR SIGFOX 06

609

648

523

533

320

321

200

568

502

157

175

130

165

22

JBRB ECOWATT® PR - PR SIGFOX 10

616

648

566

583

421

440

250

569

544

207

185

166

198

26

JBRB ECOWATT® PR - PR SIGFOX 22

756

789

683

701

511

530

355

709

661

252

237

236

271

45

JBRB ECOWATT® PR - PR SIGFOX 30

973

1019

820

873

565

585

400

892

797

267

271

248

286

64

JBRB ECOWATT® PR - PR SIGFOX 38

1106

1153

938

971

637

656

500

1036

907

306

331

315

350

78

* IS version: +27 mm ** JBRB ECOWATT PR version only ***JBRB ECOWATT PR SIGFOX, IS version: +10 mm


JBRB ECOWATT® PR - PR SIGFOX 48 / 70 / 82 / 92 - L / M
Vertical discharge
 

--- Available only on the "M" modular version

Model

A**

A

B

B'

C* and **

C***

D1

E

F

G

H

I

J

Weight (kg)

JBRB ECOWATT® PR - PR SIGFOX 48

1119

1165

985

1065

800

819

560

700

918

433

330

320

340

107

JBRB ECOWATT® PR - PR SIGFOX 70

1234

1280

1030

1100

880

900

630

815

970

473

365

370

375

121

JBRB ECOWATT® PR - PR SIGFOX 82

1358

1404

1100

1175

970

988

710

846

1032

518

405

482

415

170

JBRB ECOWATT® PR - PR SIGFOX 92

1358

1404

1100

1175

970

988

710

846

1032

518

405

482

415

170

* IS version: +27 mm ** JBRB ECOWATT PR version only ***JBRB ECOWATT PR SIGFOX, IS version: +10 mm

JBRB ECOWATT® PR - PR SIGFOX 10 / 22 / 30 / 38 - D
Horizontal discharge



Model

A**

A

B

C* and **

C***

D1

D2

E

F

G

H

I

J

Weight 
(kg)

JBRB ECOWATT® PR - PR SIGFOX 10

815

837

603

421

440

250

200

777

544

194

161

207

186

28

JBRB ECOWATT® PR - PR SIGFOX 22

1048

1070

720

511

530

355

315

998

661

239

219

252

239

45

JBRB ECOWATT® PR - PR SIGFOX 30

1324

1324

930

566

585

400

355

1238

797

267

247

267

271

67

JBRB ECOWATT® PR - PR SIGFOX 38

1468

1468

1024

631

656

500

400

1396

908

306

281

306

331

83

* IS version: +27 mm

JBRB ECOWATT® PR - PR SIGFOX 48 / 70 / 82 / 92 - D
Horizontal discharge

Model

A

B

C* and **

C***

D1

D2

E

F

G

H

I

J

Weight
(kg)

JBRB ECOWATT® PR - PR SIGFOX 48

1490

1105

800

819

560

450

990

918

433

270

433

330

135

JBRB ECOWATT® PR - PR SIGFOX 70

1691

1183

880

900

630

500

986

978

473

301

473

365

150

JBRB ECOWATT® PR - PR SIGFOX 82

1813

1237

970

988

710

560

1016

1032

518

340

518

405

200

JBRB ECOWATT® PR - PR SIGFOX 92

1813

1237

970

988

710

560

1016

1032

518

340

518

405

200

* version IS: +27 mm

JBRB ECOWATT® PR - PR SIGFOX 10 / 22 / 30 / 38 - D
Vertical discharge

 

Modèle

A**

A

B

C* et **

C***

D1

D2

E

F

G

H

I

J

Poids
(kg)

JBRB ECOWATT® PR - PR SIGFOX 10

804

837

603

421

440

250

200

777

544

194

161

166

198

28

JBRB ECOWATT® PR - PR SIGFOX 22

1037

1070

720

511

530

355

315

998

661

239

219

236

271

45

JBRB ECOWATT® PR - PR SIGFOX 30

1276

1308

930

566

585

400

355

1238

797

267

247

248

286

67

JBRB ECOWATT® PR - PR SIGFOX 38

1426

1468

1025

637

656

500

400

1396

909

306

281

315

350

83

* IS version: +27 mm

JBRB ECOWATT® PR - PR SIGFOX 48 / 70 / 82 / 92 - D
Vertical discharge



Model

A**

A

B

C* and **

C***

D1

D2

E

F

G

H

I

J

Weight 
(kg)

JBRB ECOWATT® PR - PR SIGFOX 48

1444

1490

1105

800

819

560

450

990

918

433

270

320

340

135

JBRB ECOWATT® PR - PR SIGFOX 70

1691

1737

1183

880

900

630

500

986

978

473

301

370

375

150

JBRB ECOWATT® PR - PR SIGFOX 82

1767

1813

1237

970

988

710

560

1016

1032

518

340

482

415

200

JBRB ECOWATT® PR - PR SIGFOX 92

1767

1813

1237

970

988

710

560

1016

1032

518

340

482

415

200

* IS version: +27 mm

Close Open Performance / Environment Certificates

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

EASYVENT
Access the software online Media locked
Axial selection software and S&P group products

  • Creation of a technical sheet per fan including the operating point requested on the curve, the technical and acoustic characteristics, and the dimension drawings
  • Printing possibility
  • Link to all technical catalog pages

OPTAIR RT Conso
Download OPTAIR Conso Media locked
Selection software for collective ventilation units - Calculation of electrical consumption
For any operating problem, please send your request by email to optair@vim.fr
RTConso-2018.jpg
  • Automatic calculation of minimum / maximum flow rates DTU 68.3 and RT2012
  • Selection of suitable fans
  • Detailed technical sheet with fan consumption determined according to its operating point, according to Th-BCE rules
  • Automatic update of the application (requires an internet connection)

March 2021: new version (automatic update)

  • In tertiary rapid calculation, possibility of selecting turrets / KUBAIR

  • Modification of ranges: HUCF ECO PR, TEDV / TEDH ECOWATT C4, JRBR ECOWATT / JRBR ECOWATT PR / JRBR ECOWATT PM (sizes 30 and 38), JRBR ECOWATT Sigfox / JRBR ECOWATT PR Sigfox / JRBR ECOWATT PM Sigfox (sizes 30 and 38) , KUBAIR ECOWATT (Mono)

  • Addition of the JBRE ECOWATT, JBRE ECOWATT PR ranges

Download user manual
OPTAIR VMC
Download OPTAIR VMC 2018 Media locked
VMC installation sizing and quotation software
For any operating problem, please send your request by email to optair@vim.fr

  • Network sizing and selection of the suitable fan.
  • Works for any self-adjusting, hygro-adjustable and gas installation.
  • Calculations in accordance with current standards.
  • Provides a detailed and costed list of the selected material.
  • Allows the production of quotes from the database of VIM products.
  • Possible application in TERTIARY single-flow CMV.

August 2020: new version (automatic update)

  • Addition of TED F400 ECOWATT COP and KUBAIR F400 ECOWATT COP (in rapid collective VMC project and in full project)
  • Addition of K STD and K STD IP 16
  • Removal of K STD and K STD IP 19
Download user manual