KUBAIR® F400 ECOWATT® CC / MV

F400 120 extraction boxes

Direct drive - Reaction - ECM < 24000 m3/h

KUBAIR F400 ECOWATT® View larger

KUBAIR® F400 ECOWATT® CC / MV

F400 120 extraction boxes


Direct drive - Reaction - ECM < 24000 m3/h

ErP.jpg ErP 2018 compliant - UVNR
Variable EC motor
f400-c4.jpg CE.jpg moteur-ecm.jpg vmc-hygro.jpg COP-CAV-VAV.jpg
GTC-MODBUS.jpg isolation-acoustique.jpg Maintenance.jpg logiciels.jpg

  • F400 120 approved without relay box and 400 ° C 1 / 2h C4
  • Low consumption ECM motor
  • Integrated regulation VAV, CAV, COP, ASR
  • Flow or pressure display
  • Communicating ModBus
  • Multidirectional connection
  • Waterproof kitchen version

Application

CMV collective and tertiary housing.
Extraction of fumes and hot gases in case of fire.
Extraction of stale air from tertiary and industrial premises.
Extraction of pollutants in professional kitchens.
Installation in all positions and connection on all sides, except with vertical motor axis and motor at the bottom.
Air extraction up to 120 ° C continuously, ECM motor at -10 ° C + 40 ° C max.
In the current state of the standard, this range cannot be associated with an NF certified relay box.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow from 500 to 24,000 m3/h.
6 sizes: 355 / 400 / 450 / 500 / 630 / 710.
Models:
  • KUBAIR® F400 ECOWATT® CC: complete unit with multidirectional suction plenum, horizontal or vertical axis motor.
  • KUBAIR® F400 ECOWATT® MV: ventilation unit only, horizontal or vertical axis motor.


Options - Corrosion treatment


KUBAIR F400 - Main spare parts


Versions
  • KUBAIR® F400 ECOWATT® manual control by potentiometer.
  • KUBAIR® F400 ECOWATT® VAV with flow rate display.
  • KUBAIR® F400 ECOWATT® COP with pressure display.
  • KUBAIR® F400 ECOWATT® CAV with flow rate display.
  • KUBAIR® F400 ECOWATT® ASR with pressure display for association with a single-flow CTA VIM , ASR ECOWATT system®.

Construction
  • Interchangeable galvanized sheet steel panels.
  • Modular structure in aluminum profiles.
  • 4 fixing brackets.
  • Connection by 2 interchangeable smooth KUBZ12 flanges included.
  • Galvanized steel reaction turbine, mounted in direct coupling with the motor.
  • Full access for cleaning and maintenance without uncoupling the housing.

Motorization
  • ECM motor, class F, three-phase with remote IP55 controller:
    • Single-phase 230V 50/60Hz power supply controller for sizes 355 to 450.
    • 400V 50/60Hz three-phase power supply controller for sizes 500 to 710.
  • Thermal protection built into the controller.

ETDZ Remote control - Accessory
  • ModBus IP21 touch control, 3m RJ12 cable.
  • On/Off function.
  • 0-10V speed control in VAV mode.
  • Display of set point and rotation speed.
  • Display of consumption and faults.
  • Magnetically attached shockproof case included.
KUBZ 14 - Kitchen Option
  • Reinforced sealing with grease resistant gasket.
  • Drain purge supplied not fitted.
  • Uninsulated double skin.
KUBZ 16 - Overpressure damper
  • Ensures a good air and water tightness when the casing is stopped.
  • Accessory for horizontal shaft motor box. Consult us.
KUBZ 17 - Overpressure damper
  • Ensures a good air and water tightness when the casing is stopped.
  • Accessory for vertical shaft motor box. Consult us.

Communication
  • ModBus RTU in RS485 port.

Flow or pressure display
  • VAV display of the measured flow in m3/h. Accuracy ±2.5%.
  • CAV display of the measured flow in m3/h. Accuracy ±2.5%.
  • COP display of the pressure measured in Pa. Accuracy ±2.5%.

Smoke extraction operation
  • The KUBAIR® F400 ECOWATT® is approved for the extraction of hot gases and smoke in the event of fire. This operating mode is automatic and does not require any configuration: in the event of gas extraction at a temperature > 200°C, the box will automatically switch to GV with its internal thermal protections inhibited.
  • The smoke extraction mode can also be triggered manually with a BDRA type control box.
  • CAV/VAV/COP modes are no longer taken into account.

F400 120 factory-fitted and approved electrical equipment:
  • C1-CR1 cable protected by a flexible outer sheath (excellent UV resistance).
  • INTZ: padlockable proximity switch with 2 auxiliary contacts (1 NO and 1 NC).
  • PTHV-A: Pressure transmitter with flow or pressure display. It displays the flow in VAV control.
  • VCHV-A: Pressure or flow regulator for COP and CAV regulation with display.
Selection of smoke extraction fans
MV version
Assembly with horizontal motor axis


CC version
Assembly with horizontal motor axis


MV version
Assembly with vertical motor shaft


CC version
Assembly with vertical motor shaft


Size

A

BH

BV

BVC

C

D

E

EC

F

G

355

627

695

327

645

263

559

606

790

660

31

400

699

767

361

678

297

631

606

864

732

31

450

779

847

392

738

326

711

606

990

812

31

500

858

925

424

784

338

768

700

1039

890

42

630

1066

1133

488

912

403

977

700

1183

1098

42

710

1194

1261

551

1032

462

1104

906

1325

1226

42


Size

GC

H

J

K

KC

L

Weight MV (Kg)

CC Weight (Kg)

Naked

Isolated

Naked

Isolated

355

50

315

102

826

1103

321

44.4

47.5

64.9

71.0

400

50

349

102

860

1170

321

55.2

59.2

78.2

86.2

450

50

378

102

892

1230

321

72.5

77.5

97.4

107.5

500

62

402

112

954

1294

351

93.8

99.5

120.1

131.5

630

62

466

112

1018

1422

351

132.1

139.1

176.3

194.1

710

62

526

112

1070

1533

446

158.0

167.1

278.8

302.2

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Specification text (TP)

OPTAIR Ventilation
Download OPTAIR Ventilation Media locked
Selection software for turrets and extraction boxes / introduction: KDT / KSH / TCD / KUBAIR / TED
For any operating problem, please send your request by email to optair@vim.fr

  • Creation of a technical sheet per fan including the operating point requested on the curve, the technical and acoustic characteristics, and the dimension drawings
  • Printing possibility
  • Link to all technical pages Catalog
January 2024 - New version OPTAIR Ventilation 2024.1.2.0
  • Integration of the tariff on 01/02/2024
  • Obsolete engine removals
  • Miscellaneous Corrections

BURGER KING - VILLEPARISIS

Close Open BURGER KING - VILLEPARISIS

Restaurant chains

77 - Seine-et-Marne


Installed products:


Close Open HOTEL IMPERATOR

Hotels

30 - Gard

LE GRAND REFECTOIRE DE L'HOTEL DIEU

Close Open LE GRAND REFECTOIRE DE L'HOTEL DIEU

Independent commercial catering

69 - Rhône

LYCEE CHABRIER - YSSINGEAUX

Close Open LYCEE CHABRIER - YSSINGEAUX

High schools

43 - Haute-Loire


Installed products:


LYCEE HOTELIER SAVARY

Close Open LYCEE HOTELIER SAVARY

High schools

62 - Pas-de-Calais

LYCEE PROFESSIONNEL - AUBIN

Close Open LYCEE PROFESSIONNEL - AUBIN

High schools

MEDIATHEQUE L'AGORA - METZ

Close Open MEDIATHEQUE L'AGORA - METZ

Media library

57 - Moselle

Close Open NINKASI - ANDREZIEUX-BOUTHEON

Restaurant chains

42 - Loire

NINKASI - LYON

Close Open NINKASI - LYON

Restaurant chains

69 - Rhône

Close Open NINKASI - ST ETIENNE

Restaurant chains

42 - Loire

Close Open NINKASI - VILLEFRANCHE

Restaurant chains

69 - Rhône

PAUL BOCUSE

Close Open PAUL BOCUSE

Independent commercial catering

69 - Rhône

WALIBI

Close Open WALIBI

Recreation centers

38 - Isère

X