KSHA - KSHR

Extraction or insufflation boxes

Transmission - Forward or Backward < 50000 m3/h

KSHA - KSHR View larger

KSHA - KSHR

Extraction or insufflation boxes


Transmission - Forward or Backward < 50000 m3/h

PIC-ERP-conforme-01.jpg KSHR - ErP 2018 UVNR Compliant

KSHA - Not ErP Compliant
For smoke extraction alone or process ventilation

PIC-coffret-monte.jpg PIC-LOGICIEL-01.jpg

  • Fan action or reaction
  • Wide range of flow and pressure
  • Robust construction
  • Complete solution with mounted electrical accessories


Applications:

Extraction or insufflation.
Introduction of smoke extraction air.
Installation inside buildings or on the terrace.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

11 sizes: 200 / 250 / 280 / 315 / 355 / 400 / 450 / 500 / 560 / 630 / 710 mm.
Discharge: horizontal or vertical.

KSHA
  • Action wheel.
  • Flow rate from 1 000 to 50 000 m3/h.
  • Pressure from 120 to 1 500 Pa.
KSHR
  • Reaction impeller.
  • Flow rate from 500 to 40 000 m3/h.
  • Pressure from 240 to 2 000 Pa.

KSHA - KSHR - Main spare parts


Options - Anti-corrosion treatment


Construction
  • One-piece casing made of galvanized steel sheet Z275, completely removable.
  • Side panels removable on both sides for easy access.
  • KSHA dynamically balanced double inlet galvanized steel turbine, small size, high flow capacity.
  • KSHR double jet turbine in painted galvanized steel, dynamically balanced, medium pressure, stable flow, insensitive to fouling.
  • Motor-turbine mounted on a thick folded longitudinal frame.
  • Connection by smooth rectangular flanges for suction and discharge.
  • Suction and discharge in line (horizontal version) or discharge on top (vertical version).
  • Two transverse omegas ensure the rigidity of the unit and allow the passage of slings for lifting.

Transmission
  • Transmission-motor assembly mounted inside the box.
  • Driven by V-belts and pulleys with 1 to 5 grooves (depending on the motor power).
  • Standard motor access on the left (air direction), on the right on request.

Filtration as accessory
  • FIGR G4 Coarse pleated filters 70%,
  • Minipleat filters FIFI M5 ePM10 75%,
  • Minipleat filters FIFI F7 ePM1 55%.

Motorization
  • Motor mounted on slide plate for belt tension adjustment.
  • AC motors with B3 legs, IP55 class F. Integrated thermal protection PTO to be connected:
    • 1 speed single phase 230V, 50Hz, 2 or 4 poles.
    • 1 three-phase speed 230/400V, 50Hz P ≤ 7.5 kW, 2, 4, 6 or 8 poles IE1, IE2, IE3.
    • 1 speed three phase 400/690V, 50Hz P > 7.5 kW, 2, 4, 6 or 8 poles IE1, IE2, IE3.
    • 2 speed three phase 400V, 50Hz, 2/4, 4/8 and 6/12 poles. Dalhander, 4/6 and 6/8 independent windings.
  • AC 1 speed three phase motors. Frequency converter compatible, range 15 to 50Hz.
  • 60Hz single-phase or three-phase power supply: consult us.

Selection - Standard fans
Horizontal discharge configuration
Sizes 200 to 560



Sizes 630 and 710 


Model

AH

AV

B

C

CV

D

E

F

G

H

M

N

P

Q

R

Motor max.

Weight*

200

993

981

595

703

742

555

680

400

500

258

249

392

500

28

125

112

54

250

1130

1118

727

784

824

679

766

500

600

324

221

411

569

28

125

132

63

280

1177

1168

824

776

816

780

777

600

700

362

146

379

609,5

28

125

132

79

315

1360

1329

896

876

916

860

767

600

700

408

221

416

683,5

28

125

132

100

355

1490

1457

1006

990

1030

966

897

700

800

457

221

476

744

28

125

160

133

400

1594

1565

1120

1036

1078

1071

926

800

900

509

184

471

753

28

125

160

196

450

1761

1734

1191

1119

1162

1143

1130

900

1000

570

184

486

825

39

182

180

214

500

1919

1891

1387

1222

1264

1340

1180

900

1000

640

249

521

964

39

182

200

259

560

1919

1891

1387

1269

1310

1340

1180

1000

1100

718

189

492

999

39

182

200

288

630

2132

2104 1575 1464 1473 1507 1016 1200 1300 806 566 177 1070 44 240 200 467

710

2292 2264 1765 1614 1623 1697 1176 1200 1400 900 286 617 1125 44 240 200 561

* Fan weight (kg) without motor, with transmission. Engine weight see MOT.


Vertical discharge configuration
Sizes 200 to 560
KSHA-R-V-dim.png


Sizes 630 and 710



Model

AH

AV

B

C

CV

D

E

F

G

H

M

N

P

Q

R

Motor max.

Weight*

200

993

981

595

703

742

555

680

400

500

258

249

392

500

28

125

112

54

250

1130

1118

727

784

824

679

766

500

600

324

221

411

569

28

125

132

63

280

1177

1168

824

776

816

780

777

600

700

362

146

379

609,5

28

125

132

79

315

1360

1329

896

876

916

860

767

600

700

408

221

416

683,5

28

125

132

100

355

1490

1457

1006

990

1030

966

897

700

800

457

221

476

744

28

125

160

133

400

1594

1565

1120

1036

1078

1071

926

800

900

509

184

471

753

28

125

160

196

450

1761

1734

1191

1119

1162

1143

1130

900

1000

570

184

486

825

39

182

180

214

500

1919

1891

1387

1222

1264

1340

1180

900

1000

640

249

521

964

39

182

200

259

560

1919

1891

1387

1269

1310

1340

1180

1000

1100

718

189

492

999

39

182

200

288

630

2132

2104 1575 1464 1473 1507 1016 1200 1300 806 566 177 1070 44 240 200 467

710

2292 2264 1765 1614 1623 1697 1176 1200 1400 900 286 617 1125 44 240 200 561

* Fan weight (kg) without motor, with transmission. Engine weight see MOT.

Close Open Detailed specifications

Text catalog pages (CT)

Text catalog pages (CT) Other languages

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other

Installation instructions (NT) Other languages

Close Open Fire / Smoke extraction certificates

Fire classification report (PVFEU)

Close Open Performance / Environment Certificates

ErP regulatory sheet (FERP)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

Commercial leaflet (FCOM)

OPTAIR Ventilation
Download OPTAIR Ventilation Media locked
Selection software for turrets and extraction boxes / introduction: KDT / KSH / TCD / KUBAIR / TED
For any operating problem, please send your request by email to optair@vim.fr

  • Creation of a technical sheet per fan including the operating point requested on the curve, the technical and acoustic characteristics, and the dimension drawings
  • Printing possibility
  • Link to all technical pages Catalog
January 2024 - New version OPTAIR Ventilation 2024.1.2.0
  • Integration of the tariff on 01/02/2024
  • Obsolete engine removals
  • Miscellaneous Corrections

Close Open CENTRE DE CONGRES COUVENT DES JACOBINS (VENTIL.) - RENNES

Performance halls

35 - Ille-et-Vilaine

Close Open CH - BOULOGNE

Hospitals

62 - Pas-de-Calais

CLUB MED ALPES D'HUEZ

Close Open CLUB MED ALPES D'HUEZ

Hotel residences

38 - Isère

GRAND STADE - LILLE

Close Open GRAND STADE - LILLE

Stadiums

59 - North

HOPITAL CARDIO VASCULAIRE PULMONAIRE - LILLE

Close Open HOPITAL CARDIO VASCULAIRE PULMONAIRE - LILLE

Hospitals

59 - North

Close Open HOPITAL NECKER PARIS

Hospitals

75 - Paris


Installed products:


Close Open IMMEUBLE DE BUREAUX PULSE - CONSTRUCTION HQE 28000 M2

Housing complex

93 - Seine-Saint-Denis

Close Open LES TERRASSES DU PORT - MARSEILLE

Shopping centers

13 - Bouches-du-Rhône

Close Open POLE ECOTOX - ALIXAN

Healthcare establishments

26 - Drome

X