CAD HR MINI

Double flow air handling unit H with exchanger

Counter flow - Backward - ECM < 600 m3/h

Flag Nouveau
CAD HR MINI HL View larger

CAD HR MINI

Double flow air handling unit H with exchanger


Counter flow - Backward - ECM < 600 m3/h

Conformes ErP 2018 - UVNR - Moteur EC variable ErP 2018 compliant - UVNR
Variable EC motor
Filters
Delivered as standard: Blowing new look and reprise Stale air: FIFI F7 ePM1 70 mini pleat filters% 373x230x25mm.
Echangeur à contre-courant Moteur ECM By-pass
GTC Modbus / BACnet Régulation Plug & play OPTAIR® CTA
Logo-EUROVENT.jpg
Air-air plate heat exchangers produced by the company RECUTECH which participates in the Eurovent Certification program for AAHE.




  • New construction and regulation
  • Numerous possibilities for controlling external batteries
  • Double skin insulation 25 mm
  • Low consumption ECM motors
  • Communicating Modbus / BACnet control
  • Thermal efficiency up to 92%

Applications:

Single-zone tertiary premises th category: air introduction and extraction with energy recovery.
Indoor use only.
Horizontal suspended installation.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

1 size: 500m3/h.
Horizontal construction (H)
In-line duct connection configurations (L).
Right (R) or left (L) easement in the direction of the blown air.
Bypass 100% modulating.
Control of external antifreeze and post-heating or cooling batteries (accessories).
EVCO regulation with remote touch control, communicating Modbus on RS485 or IP port, and BACnet IP.

Construction
  • Double skin panel:
    • Exterior: Panels in zinc magnesium ZM310, corrosion resistance C5, 25 mm thick insulation of injected polyurethane foam (42 kg/m3, 0.0246W/mk) fire rating B-S2, d0.
    • Interior: Panels in zinc magnesium ZM310, corrosion resistance C5.
  • Condensate tray with drain Ø 3/8'' Gas.
  • Access to the exchanger from below thanks to a removable panel.
  • Quick access to the filters and fans from below via slide-in hatches.

Motorization
  • Composite material reaction freewheel type fan.
  • Low consumption ECM electronically commutated motor, single phase (230V-1-50/60 Hz) input 0...10V.

exchanger
  • High efficiency counter-current heat exchanger.
  • In aluminium.
  • Motorized bypass 100%, integrated into the unit, fitted with a 230V single-phase 3-point servo-motor controlled proportionally by acting on the running time.
  • Airtightness according to standard EN 13141-7:
    • Internal leakage: class A2; external leakage: class A1.

Filters
  • Fresh air supply and stale air return: FIFI F7 ePM1 70 mini pleat filters% 373x230x25mm.

Air treatment selection

Horizontal construction with in-line connection (HL)




Outdoor air
Extract air
Supply air
Exhaust air

Close Open Detailed specifications

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Close Open Fire / Smoke extraction certificates

Close Open Performance / Environment Certificates

ErP regulatory sheet (FERP)

Eurovent certificate (CEUR)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

Close Open ESAT ST DIE

Manufacturing premises

88 - Vosges

Close Open MAIF SIEGE - NIORT

Community restaurants / RIE

79 - Deux-Sèvres

RESIDENCE GALLOIS VILLAGE (301 ACCOMMODATIONS) - VILLENEUVE D'ASCQ

Close Open RESIDENCE GALLOIS VILLAGE (301 ACCOMMODATIONS) - VILLENEUVE D'ASCQ

Student residences

59 - North


Installed products:


Close Open RESIDENCE GALLOIS VILLAGE (301 LOGEMENTS) - VILLENEUVE D'ASCQ

Student residences

59 - North

X