TEDH F400 ECOWATT® - TEDV F400 ECOWATT®

Roof fans F400 120

Centrifuges - Reaction - ECM < 26000 m3/h

TEDH F400 ECOWATT 450 View larger

TEDH F400 ECOWATT® - TEDV F400 ECOWATT®

Roof fans F400 120


Centrifuges - Reaction - ECM < 26000 m3/h

PIC-Conforme-ErP.jpg ErP 2018 compliant - UVNR
Variable EC motor
F400.jpg Conformite-europeenne.jpg debit-pression-regule.jpg GTC-modbus.jpg
moteur-ecm.jpg vmc-hygro.jpg logiciel.jpg

  • Low consumption ECM motor
  • High performance jet turbine
  • F400 120 approved without relay box and 400 ° C 1 / 2h C4
  • Integrated regulation VAV, CAV, COP, ASR
  • Flow or pressure display
  • Communicating ModBus
  • Continuous operation up to 120 ° C

CMV collective and tertiary housing.
Extraction of stale air from tertiary and industrial premises.
Ventilation and smoke extraction in professional kitchens.
Maximum temperature of the extracted air in permanent mode: 120 ° C.
In the current state of the standard, this range cannot be associated with an NF certified relay box.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flows from 200 to 24,000 m3/h.
6 sizes: 355 / 400 / 450 / 500 / 630 / 710.

Models
  • TEDH F400 ECOWATT® : horizontal rejection
  • TEDV F400 ECOWATT® : vertical rejection
    • Engine and turbine not visible.
    • Less fouling of the immediate surroundings.

Versions
  • TEDH/V F400 ECOWATT® manual control with potentiometer.
  • TEDH/V F400 ECOWATT® VAV with flow rate display.
  • TEDH/V F400 ECOWATT® COP with pressure display.
  • TEDH/V F400 ECOWATT® CAV with flow rate display.
  • TEDH/V F400 ECOWATT® ASR with pressure display for association with a single-flow CTA VIM , ASR ECOWATT system®.


OPTIONS - CORROSION TREATMENT


Construction
  • High performance reaction turbine in galvanized steel.
  • Convergent/divergent type suction hood for aeraulic optimization and increased performance of the turret, with reduced sound levels.
  • Direct coupling on the motor shaft.
  • Motor controller fixed on a closed rejection face.
  • Plate, arm and motor support in galvanized steel.
  • 4 lifting lugs depending on model.
  • 4 lifting slings.
  • Arm trims in RAL 7024 gray pre-lacquered sheet metal:
    • Neat finish of the turret.
    • Easy disassembly to access the turret fixing points.
  • Protective mesh in pre-lacquered gray RAL 7024 galvanized steel sheet. Meshes in accordance with standard NF EN ISO 12499.
  • Cap in ABS PMMA gray RAL 7024:
    • Enhancing aesthetics.
    • Motor and display protection.
    • Excellent UV and weather resistance.
    • Very good impact resistance.
  • Vertical discharge version: addition of 3 deflectors in RAL 7024 pre-lacquered sheet metal delivered factory-fitted (TEDV F400 ECOWATT model®) or available as a kit for on-site assembly (KRVT).
  • The RAL 7024 gray pre-painted sheet metal is of atmospheric corrosivity category C5 according to NF EN ISO 12944-2.

Motorization
  • ECM motor, class F, with remote IP55 controller:
    • Single-phase 230V 50/60Hz power supply controller for sizes 355 to 450.
    • Three-phase 400V 50/60Hz power supply controller for sizes 500 to 710.
  • Thermal protection built into the controller.

Communication
  • ModBus RTU in RS485 port.

ETDZ Remote control
  • ModBus IP21 touch control, 3m RJ12 cable. provided.
  • On/Off function.
  • 0-10V speed control in VAV mode.
  • Display of set point and rotation speed.
  • Display of consumption and faults.
  • Magnetically attached shockproof case included.

Flow or pressure display
  • VAV display of the measured flow in m3/h. Accuracy ±2.5%.
  • CAV display of the measured flow in m3/h. Accuracy ±2.5%.
  • COP display of the pressure measured in Pa. Accuracy ±2.5%.

Smoke extraction operation
  • TED F400 ECOWATT® is approved for the extraction of hot gases and smoke in the event of a fire. This operating mode is automatic and does not require any configuration: in the event of gas extraction at a temperature > 200°C, the turret will automatically switch to GV with its internal thermal protections inhibited.
  • The smoke extraction mode can also be triggered manually with a BDRA type control box.
  • CAV/VAV/COP modes are no longer taken into account.

F400 120 factory-fitted and approved electrical equipment:
  • C1-CR1 cable protected by a flexible outer sheath (excellent UV resistance).
  • INTZ: padlockable proximity switch, with 2 auxiliary contacts (1 NO and 1 NC), visibility of the rotary knob only and increased weather protection.
  • PTHV-A: pressure transmitter with visible flow or pressure display. Integrated under the cap, it displays the flow in VAV control.
  • VCHV-A: Pressure or flow regulator for COP or CAV regulation with display, integrated under the cap.

F400 120 Approved Mounting Accessories
  • TCDZ 01 to 09, SILS muffler, POPM blanking plate, KRVT vertical kit.
  • TCDZ 12: Galvanized steel overpressure damper. Ensures a good air and water seal when the turret is stopped. Option delivered mounted on the TEDV ranges - Provide as many TCDZ 12 as there are discharge faces.
  • TCDZ 14: Galvanized steel overpressure damper. Ensures a good air and water seal when the turret is stopped. Accessories to be fitted to the TEDV ranges already delivered - Provide as many TCDZ 14s as there are discharge faces.
  • TCDZ 15: overpressure damper + vertical deflector in galvanized steel. Ensures a good air and water seal when the turret is stopped. Accessories to be mounted on the TEDH ranges already delivered - Provide as many TCDZ 15s as there are discharge faces.
  • POPM: blanking plate of a rejection face for TEDH for installation of the turret near a wall (or an obstacle to gas evacuation), or in a corner or between 2 other turrets with 2 POPM. Saves space and avoids the rejection of air and dirt directly on the wall.
  • Laboratory tests have made it possible to verify that the vertical discharge kit and the blanking plate on one side have no effect on the aeraulic, acoustic and electrical performance of the turret.

Selection of smoke extraction fans
TEDH F400 ECOWATT®

Model

A

B

CH

D

E

F

P

Weight (Kg)

355

540

570

754

289.1

450

30

146

34

400

540

609

754

325.8

450

30

169

44

450

660

684

864

366.5

570

30

190

57

500

660

700

867

407.3

570

30

198

83

630

800

805

1045

513.1

668

30

234

106

710

946

1089

1223

577.9

830

40

273

165




TEDV F400 ECOWATT®
TEDV-ECO-dim.png

Model

A

B

CV

D

E

F

Weight (Kg)

355

540

570

901

289.1

450

30

38

400

540

609

926

325.8

450

30

49

450

660

684

1051

366.5

570

30

63

500

660

700

1070

407.3

570

30

94

630

800

805

1279

513.1

668

30

116

710

946

1089

1489

577.9

830

40

179

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

EASYVENT
Access the software online Media locked
Axial selection software and S&P group products

  • Creation of a technical sheet per fan including the operating point requested on the curve, the technical and acoustic characteristics, and the dimension drawings
  • Printing possibility
  • Link to all technical catalog pages

OPTAIR Ventilation
Download OPTAIR Ventilation Media locked
Selection software for turrets and extraction boxes / introduction: KDT / KSH / TCD / KUBAIR / TED
For any operating problem, please send your request by email to optair@vim.fr

  • Creation of a technical sheet per fan including the operating point requested on the curve, the technical and acoustic characteristics, and the dimension drawings
  • Printing possibility
  • Link to all technical pages Catalog
January 2024 - New version OPTAIR Ventilation 2024.1.2.0
  • Integration of the tariff on 01/02/2024
  • Obsolete engine removals
  • Miscellaneous Corrections

3 BRASSEURS

Close Open 3 BRASSEURS

Restaurant chains

59 - North

Close Open ECOLE DE TOUSSIEU - CONSTRUCTION RESTAURANT SCOLAIRE ET 4 CLASSES

Community restaurants / RIE

69 - Rhône

ECOLE HOTELIERE DE BIARRITZ

Close Open ECOLE HOTELIERE DE BIARRITZ

Specialized education

64 - Pyrénées-Atlantiques

LYCEE B. FRANKLIN - ORLEANS

Close Open LYCEE B. FRANKLIN - ORLEANS

High schools

45 - Loiret

Close Open LYCEE FRANCOIS CEVERT - ECULLY - RESTRUCTURATION

High schools

69 - Rhône

MEDIATHEQUE L'AGORA - METZ

Close Open MEDIATHEQUE L'AGORA - METZ

Media library

57 - Moselle

THE ROSTER - ANNECY

Close Open THE ROSTER - ANNECY

Independent commercial catering

74 - Haute-Savoie

X