JBHB ECO PR

Old ranges

Direct drive - Forward < 800 m3/h

FLAG Obsolete
JBHB ECO PR 05 L View larger

JBHB ECO PR

Old ranges


Direct drive - Forward < 800 m3/h

PIC-ERP-conforme-01.jpg Sizes 05/08 - ErP compliant - UVR - Variable speed drive
PIC-C4-confort-01.jpg PIC-regulation-COP-01.jpg PIC-ATEC-HYGRO-CSTB-01.jpg PIC-Isolation-acoustique-01.jpg PIC-LOGICIEL-01.jpg

  • Low power consumption
  • Low noise level
  • Constant pressure

Application

Air extraction.
Indoor or outdoor installation.
400 ° C 1 / 2h category C4 approved - PTO not connected.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow rates from 50 to 800 m3 / h, pressure from 50 to 180 Pa.
Constant pressure operation.
Insulated version: M0 25 mm glass wool.
With INTZ or with INTZ + BDEZ.


Construction

  • Galvanized sheet steel casing.
  • Connection taps with class D sealing gaskets.
  • Direct coupling.
  • IP55 regulation box.
  • INTZ : padlockable proximity switch with mounted / wired position feedback.
  • BDEZ : pressure switch fitted, air-connected, factory set to 80 Pa (version with INTZ + BDEZ).
  • Single inlet forward fan.
    • Mono electronic voltage regulator. 230 V, wired with the motor.
    • Asynchronous motor outside the IP10 class F mono air flow. 230V 50Hz.

Fan selection C4 - 400 ° C 1 / 2H

JBHB ECO PR 05/08


Box positioned in vertical discharge
JBHB-ECO-PR-05-08-V-dim.png




Model

Config.

Dimensions

A

B

C

D1

D2

E

JBHB ECO PR 05

L, C, D

550

504

300

200

160

130

JBHB ECO PR 08

L, C, D

600

504

400

250

200

185

Model

Config.

Dimensions

F

G

H

I

J

JBHB ECO PR 05

L, C, D

148

58

53

32

132

JBHB ECO PR 08

L, C, D

181

58

53

32

132

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Installation instructions

Installation instructions (NT)

OPTAIR RT Conso
Download OPTAIR Conso Media locked
Selection software for collective ventilation units - Calculation of electrical consumption
For any operating problem, please send your request by email to optair@vim.fr
RTConso-2018.jpg
  • Automatic calculation of minimum / maximum flow rates DTU 68.3 and RT2012
  • Selection of suitable fans
  • Detailed technical sheet with fan consumption determined according to its operating point, according to Th-BCE rules
  • Automatic update of the application (requires an internet connection)

March 2021: new version (automatic update)

  • In tertiary rapid calculation, possibility of selecting turrets / KUBAIR

  • Modification of ranges: HUCF ECO PR, TEDV / TEDH ECOWATT C4, JRBR ECOWATT / JRBR ECOWATT PR / JRBR ECOWATT PM (sizes 30 and 38), JRBR ECOWATT Sigfox / JRBR ECOWATT PR Sigfox / JRBR ECOWATT PM Sigfox (sizes 30 and 38) , KUBAIR ECOWATT (Mono)

  • Addition of the JBRE ECOWATT, JBRE ECOWATT PR ranges

Download user manual
OPTAIR VMC
Download OPTAIR VMC 2018 Media locked
VMC installation sizing and quotation software
For any operating problem, please send your request by email to optair@vim.fr

  • Network sizing and selection of the suitable fan.
  • Works for any self-adjusting, hygro-adjustable and gas installation.
  • Calculations in accordance with current standards.
  • Provides a detailed and costed list of the selected material.
  • Allows the production of quotes from the database of VIM products.
  • Possible application in TERTIARY single-flow CMV.

August 2020: new version (automatic update)

  • Addition of TED F400 ECOWATT COP and KUBAIR F400 ECOWATT COP (in rapid collective VMC project and in full project)
  • Addition of K STD and K STD IP 16
  • Removal of K STD and K STD IP 19
Download user manual


X