CAD HR BASIC V

Double flow air handling unit V with exchanger

Counter flow - Backward - ECM < 5600 m3/h

CAD HR BASIC V View larger

CAD HR BASIC V

Double flow air handling unit V with exchanger


Counter flow - Backward - ECM < 5600 m3/h

erp.jpg ErP 2018 compliant - UVNR
Variable EC motors
Filters
Supplied as standard: Reprise stale air M5 (ePM10 50%). Blowing fresh air F7 (ePM1 70%) with low pressure drop.
echangeur.jpg moteur-ecm.jpg by-pass.jpg chaud-froid.jpg
regulation.jpg modbus.jpg plug-and-play.jpg logiciel.jpg
Logo-EUROVENT.jpg
Air-to-air plate heat exchanger produced by the RECUTECH company which participates in the Eurovent program. Certification for AAHE.





  • Double skin insulation 36 mm
  • With or without integrated battery
  • Freewheel reaction fan
  • Low consumption ECM motor
  • New Modbus / Bacnet communicating regulation
  • Thermal efficiency up to 90%

Application

Air introduction and extraction with heat recovery.
Installation on frame.
Use indoors or outdoors with rain protection roof.
Regulation of the blowing temperature by electric coil or water coil depending on the model.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

7 sizes: 07 (700m3/h) / 11 (1,100 m3/h) / 16 (1,600 m3/h) / 25 (2,500m3/h) / 32 (3,200 m3/h) / 45 (4,500 m3/h) / 56 (5,600 m3/h)
6 models according to types of integrated batteries:

Electric post-heater Reversible water Electric antifreeze
E
Ed
IS
EDI
RE
EDR

Vertical construction with in-line duct connection.
Right (R) or left (L) easement in the direction of the blown air.
New VIM specific integrated EVCO regulation
  • Communicating Modbus RTU on RS485 port or Modbus TCP/IP, BACnet IP, EPJcolor remote touch control.
Bypass 100% modulating.

Construction
  • Self-supporting structure in extruded aluminum profile, rounded corners.
  • 36 mm double skin panel in zinc magnesium ZM310, C5 corrosion resistance, injected polyurethane foam insulation (42 kg/m3 – 0.0246W/mk) fire classification B-S2, d0 (M1).
  • Vertical construction with in-line connection by circular tappings equipped with seals.
  • Galvanized steel frame for floor mounting.
  • Possibility of adapting the position of certain connections on site.
  • Access to filters, exchanger, battery and fan from the side.
  • Drain Ø1/2˝ for the evacuation of condensates.

exchanger
  • Aluminum plate heat exchanger, counter current, high efficiency. Thermal efficiency up to 90%.
  • Motorized bypass 100%, integrated into the unit on the fresh air network.
  • 230V single-phase 3-point servomotor drives proportionally by acting on the running time.

Motorization
  • Metal reaction freewheel type fan (incombustible A1).
  • High efficiency ECM motor, 400V 50/60Hz on size 45, 230V 50/60Hz on other sizes.
  • Control by 0…10V signal.
  • CAD HR BASIC E/EI/EC 07: IP44 Class B,
  • CAD HR BASIC E/EI/EC 11 - 16 - 25 - 32 - 45 - 56: IP54 Class B.
  • CAD HR BASIC E/EI/EC 45: IP54 Class F.
  • Electronic thermal protection.

Filters
  • Fresh air supply: FIFI F7 ePM1 70 mini pleat filters% at low pressure drop.
  • Stale air return: FIFI M5 ePM10 50 mini pleat filters%.


Electric post-heating coil EI
  • Connected to the regulator, it regulates the temperature of the blown air.
  • Equipped with safety thermostat with automatic reset (set point 55°C) and manual reset (set point 70°C).

Electric anti-freeze heater ED
  • Placed on the fresh air before the exchanger, prevents the risk of freezing on the exchanger.
  • Mounted, wired and controlled by the regulation.
  • Separate power supply, connection to specific external box equipped with a proximity switch.
  • Safety thermostat with automatic reset (set point 55°C) and manual reset (set point 70°C).

Reversible hot/cold water coil ER
  • Water coil 4 rows on sizes 07-11-23, 3 rows on other sizes.
  • Composed of copper tubes with aluminum fins on a galvanized steel frame.
  • Copper manifold.
  • Threaded connecting tube.
  • Condensate outlet to be connected to a siphon in case of cold use.
  • 230V/24V 10VA transformer for 2V or 3V valve power supply.


Air treatment selection
CADHR-BASIC-V-dim

Model

A

B

C

Ø

Weight (Kg)

CAD HR BASIC 07 V

1475

760

660

200

104

CAD HR BASIC 11 V

1645

960

760

250

140

CAD HR BASIC 16 V

2000

970

980

355

240

CAD HR BASIC 25 V

2150

1060

1180

355

268

CAD HR BASIC 32 V

2305

1460

1180

450

352

CAD HR BASIC 45 V

2465

1360

1320

500

406

CAD HR BASIC 56 V

2545

1910

1320

560

674


Possible configuration of the connections

CAD-HR-BASIC-V-config
Outdoor air
Extract air
Supply air
Exhaust air

Close Open Detailed specifications

Close Open Public tariff price

Close Open Installation instructions

Installation / maintenance manual (NT)

Installation / maintenance manual (NT) - Old version

Close Open Performance / Environment Certificates

ErP regulatory sheet (FERP)

Eurovent certificate (CEUR)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

OPTAIR CTA 2023
Download the new OPTAIR CTA 2020 version (No automatic update from the previous version) Media locked
Single or double flow CTA selection software
November 2023 – New version OPTAIR CTA 2023.12.2.0: addition of new ranges and deletion of obsolete ranges
For any operating problems, please send your request by email to optair@vim.fr

OPTAIR-CTA-1-400px.jpg
  • Sizing and price quote
  • Calculation of exchanger efficiency
  • Engine consumption
  • Selection of accessories
  • Battery characteristics
  • Acoustic characteristics

Products included in version 2023

  • Single flow CTA: KSCR ECOWATT, KSDR ECOWATT, UTBS ECOWATT, UTBS ECOWATT PRO-REG

  • Dual flow CTA: CAD O INTEGRAL, CAD HR MINI, CAD HR MINI TOP, CAD HR BASIC (V and H), CAD HR BASIC TOP, CAD HR DUO, CAD HR SLIM, CAD HR FIRST (V, H and XL), CAD HR BASIC XL

Close Open EHPAD - REMIREMONT

Residences for the elderly

88 - Vosges

ESPACE PORTE DE NIORT - SAINT JEAN D'ANGELY

Close Open ESPACE PORTE DE NIORT - SAINT JEAN D'ANGELY

Hotel residences

17 - Charente-Maritime


Installed products:


Close Open HOTEL DES 7 FONTAINES - RENOVATION EXTENSION - TOURNUS

Hotels

71 - Saône-et-Loire

LE GRAND REFECTOIRE DE L'HOTEL DIEU

Close Open LE GRAND REFECTOIRE DE L'HOTEL DIEU

Independent commercial catering

69 - Rhône

Close Open LYCEE FRANCOIS CEVERT - ECULLY - RESTRUCTURATION

High schools

69 - Rhône

Close Open MAROQUINERIE DU PUY - CHASPUZAC

Manufacturing premises

43 - Haute-Loire

X