TCRH / V ECOWATT® - TCRH / V ECOWATT® PR

Roof fans

Centrifuges - Reaction - ECM < 1200m3/h

TCRH ECOWATT® PR View larger

TCRH / V ECOWATT® - TCRH / V ECOWATT® PR

Roof fans


Centrifuges - Reaction - ECM < 1200m3/h

PIC-ERP-conforme-01.jpg ErP 2018 compliant - Variable EC motor
PIC-ATEC-GTC-MODBUS.jpg OPTAIR RT Conso

  • Low consumption ECM motor
  • Integrated potentiometer: TCRH-V ECOWATT®
  • Operation COP, CAV, VAV: TCRH-V ECOWATT® PR
  • Communicating Modbus: TCRH-V ECOWATT® PR

Applications:

Air extraction.
Outdoor installation.
Air intake in tertiary premises.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Speed: up to 1,200m3/h
Size: 225

Standard version:
  • With INTZ or with INTZ + BDEZ.
  • TCRH ECOWATT® : horizontal rejection.
  • TCRV ECOWATT® : vertical rejection.

Regulated version:
  • With RMEC + INTZ.
  • TCRH ECOWATT® PR: horizontal rejection.
  • TCRV ECOWATT® PR: vertical rejection.

  • High performance reaction turbine in galvanized steel.
  • Optimized suction pavilion.
  • Direct coupling on the motor shaft.
  • Plate, arm and motor support in Z275 galvanized steel.
  • 4 lifting legs.
  • Arm trims, protective grilles in pre-lacquered galvanized steel sheet, gray 7024. Meshes in accordance with standard NF EN ISO 12499.
  • Cap in ABS PMMA gray RAL 7024.
  • Vertical discharge version: addition of deflectors in RAL 7024 pre-lacquered sheet metal delivered factory-fitted.
  • INTZ: padlockable proximity switch with position feedback.
  • BDEZ: mounted pressure switch, aeraulic connection, factory set at 80 Pa only on TCRH-TCRV ECOWATT® version.
  • TCRH ECOWATT® : horizontal rejection on 2, 3, 4 sides (with POPM).
  • TCRV ECOWATT® : vertical rejection on 2, 3, 4 sides (with POPM).
  • TCRH ECOWATT® PR: horizontal rejection on 2 or 3 sides (with POPM).
  • TCRV ECOWATT® PR: vertical rejection on 2 or 3 sides (with POPM).

Motorization:
  • Electronically Commutated Motor (ECM):
    • IP 44, class B single phase, 230V 50Hz.
  • Thermal protection managed by electronics.

RMEC regulation: TCRH-TCRV ECOWATT® PR
  • Operation in COP (constant pressure), CAV (constant flow) or VAV (variable flow).
  • Regulation box, IP55, fitted and wired in the factory.
  • Backlit LCD display, with function keys on the front, optional remote control.
  • Clear display of the measurement (pressure, flow) and of the set point set.
  • Integrated ventilation fault indication: dry contact available on the RMEC terminal block (breaking capacity at 230Vac: 3A resistive).
  • ModBus RTU communication as standard.
Selection of standard fans
TCRH ECOWATT®


TCRV ECOWATT®


TCRH ECOWATT® PR
TCRH-ECOWATT-PR-dim

TCRV ECOWATT® PR

TCRV-ECOWATT-PR-dim

Model A B CH CV D E F H-Weight (kg) V-weight (kg)
TCRH-V ECOWATT® 430 437 436 628 185 344 30 18 19
TCRH-V ECOWATT® 567 663

Close Open Detailed specifications

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Close Open Performance / Environment Certificates

ErP regulatory sheet (FERP)

Close Open Electrical / ATEX Certificates

OPTAIR RT Conso
Download OPTAIR Conso Media locked
Selection software for collective ventilation units - Calculation of electrical consumption
For any operating problem, please send your request by email to optair@vim.fr
RTConso-2018.jpg
  • Automatic calculation of minimum / maximum flow rates DTU 68.3 and RT2012
  • Selection of suitable fans
  • Detailed technical sheet with fan consumption determined according to its operating point, according to Th-BCE rules
  • Automatic update of the application (requires an internet connection)

March 2021: new version (automatic update)

  • In tertiary rapid calculation, possibility of selecting turrets / KUBAIR

  • Modification of ranges: HUCF ECO PR, TEDV / TEDH ECOWATT C4, JRBR ECOWATT / JRBR ECOWATT PR / JRBR ECOWATT PM (sizes 30 and 38), JRBR ECOWATT Sigfox / JRBR ECOWATT PR Sigfox / JRBR ECOWATT PM Sigfox (sizes 30 and 38) , KUBAIR ECOWATT (Mono)

  • Addition of the JBRE ECOWATT, JBRE ECOWATT PR ranges

Download user manual
OPTAIR VMC
Download OPTAIR VMC 2018 Media locked
VMC installation sizing and quotation software
For any operating problem, please send your request by email to optair@vim.fr

  • Network sizing and selection of the suitable fan.
  • Works for any self-adjusting, hygro-adjustable and gas installation.
  • Calculations in accordance with current standards.
  • Provides a detailed and costed list of the selected material.
  • Allows the production of quotes from the database of VIM products.
  • Possible application in TERTIARY single-flow CMV.

August 2020: new version (automatic update)

  • Addition of TED F400 ECOWATT COP and KUBAIR F400 ECOWATT COP (in rapid collective VMC project and in full project)
  • Addition of K STD and K STD IP 16
  • Removal of K STD and K STD IP 19
Download user manual


X