KSEF ECOWATT®

Simple flow AHU

Modular - Reaction - ECM < 12 000 m3/h

Flag Nouveau
KSEF ECOWATT® View larger

KSEF ECOWATT®

Simple flow AHU


Modular - Reaction - ECM < 12 000 m3/h

Conformes ErP - UVNR - Moteur EC variable ErP 2018 compliant
UVNR - Variable EC Motor
Moteur ECM Débit ou pression régulés GTC Modbus OPTAIR® CTA VIM

  • Low consumption ECM motor
  • 25 mm double skin insulation
  • Optional M5, F7 or F9 filtration
  • Reaction freewheel fan
  • Modular design

Application

Introduction of fresh air, filtration, heating and cooling.
Indoor or outdoor installation.
Treated air temperature -25 to +40°C.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flows of 500 m3/h at 12,000m3/h.
6 sizes: 18 / 40 / 55 / 75 / 95 / 120.

Regulations and management
  • Regulation by VIM -specific integrated CORRIGO PLC.
  • 3 operating modes: variable flow (VAV), constant flow (CAV), constant pressure (COP).
  • Communicating Modbus RTU on RS485 port or Modbus TCP/IP, BACnet IP or MSTP.
  • ETD remote touch control.
Setups
  • Interiors without roof: D right easement - G left easement.
  • Exteriors with roof mounted: EXD right-hand easement - EXG left-hand easement.
Additional modules
  • KB air treatment modules:
    • KBEI electric battery module
    • KBEC hot water coil module
    • KBER reversible water coil module
  • KPCA 3-stage filtration module: Metallic / M5 + F7 / F9 + Activated carbon cartridges.
  • KSIL silent module.

Construction
  • Modular structure in aluminum profile.
  • Line construction, rectangular or circular connection.
  • Double skin panels equipped with peripheral seal:
  • Exterior in pre-lacquered galvanized steel in dark gray color RAL7024 RC5 corrosion resistance, RUV3 ultraviolet resistance according to EN 10169.
  • Z275 galvanized steel interior.
  • Glass wool insulation th. 25mm, density 24kg/m3.
  • Thermal conductivity 0.035 W/(mk) (20°C).
  • A1 fire classification according to standard EN 13 501.1.
  • Reaction freewheel fan made of non-combustible material. Mono 230V or Tri 400V ECM motor depending on size.
  • Switch fitted/wired.
  • Module delivered on feet (40 to 75) or frame (95 to 120).

2-stage filtration
  • Metallic pre-filter: FIME thickness 48 mm.
  • Pleated pre-filter: FIFI M5 ePM10 50% thickness 48mm.
  • FIFI F7 ePM1 55 mini pleat filters% or FIFI F9 ePM1 80% thickness 98mm.

Registers (accessory)
  • Manual or motorized control.
  • Water coil antifreeze protection, suction mounted.
  • Closing of the network in application of article CH38, mounted on the blowing.

KB Battery Modules
KBEI - Electric battery module
  • 304L stainless steel resistors.
  • Safety thermostats: one automatic reset thermostat 85°C, one manual reset thermostat 120°C.
  • Pulse train control.
  • Post-ventilation.
  • Separate 400V Tri-power supply with safety switch.

KBEC - Hot water coil module
  • 2 or 4 row coil, with copper tubes, aluminum fins on a galvanized steel frame; threaded connecting tubes.
  • Connection on the right or left in the direction of air flow.
  • Frost protection by contact sensor.
  • Battery(ies) mounted on slide accessible by side hatch.

KBER - Cold or reversible water coil module
  • Cold or hot water coils ER.
  • 4-row coil, with copper tubes, aluminum fins on a galvanized steel frame; threaded connecting tubes.
  • Connection on the right or left in the direction of air flow.
  • Change-over thermostat.
  • Frost protection by contact sensor.
  • Battery(ies) mounted on slide accessible by side hatch.
  • Stainless steel condensate tray and droplet separator.

Silent module
KSIL - Acoustic baffles module
  • Baffles thickness 200 mm.
  • Rockwool 50kg/m3 protected by an anti-defibration glass veil.
  • A1 fire classification.
  • Kitchen options:
    • M0 (A1) expanded metal protection to facilitate cleaning and maintain acoustic performance.
KSEF ECOWATT® 18 / 40 / 55 / 75
Indoor model without roof




Outdoor model with roof




Size A B C D E F G J M N O P Weight (kg)
Without roof With roof
KSEF ECOWATT® 18 985 644 584 538 700 100 33 154 607 985 784 796 63 73
KSEF ECOWATT® 40 1135 695 635 635 795 100 33 154 757 1135 835 891 88 120
KSEF ECOWATT® 55 1210 981 921 635 795 100 33 154 832 1210 1121 891 130 161
KSEF ECOWATT® 75 1270 981 921 921 1081 100 33 154 892 1270 1121 1177 141 156



KSEF ECOWATT® 95 / 120 / 200
Indoor model without roof




Outdoor model with roof




Size A B C D E F G N O P Weight (kg)
Without roof With roof
KSEF ECOWATT® 95 1478 1306 1226 967 1202 155 33 1478 1446 1308 230 255
KSEF ECOWATT® 120 1959 1306 1226 1272 1507 155 33 1959 1446 1613 353 385

Close Open Detailed specifications

Close Open Public tariff price

Close Open Installation instructions

Installation / maintenance manual (NT) Other

Close Open Performance / Environment Certificates

Declaration of performance (DOP)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance