CAD HR BASIC V

Double flow air handling unit V with exchanger

Counter current - Reaction - ECM < 5800 m3/h - September 2025

Flag Nouveau
CAD HR BASIC V View larger

CAD HR BASIC V

Double flow air handling unit V with exchanger


Counter current - Reaction - ECM < 5800 m3/h - September 2025

Conforme ErP 2018 - UVNR - Moteurs EC variables ErP 2018 compliant - UVNR
Variable EC motors
Filters
Supplied as standard: Blowing fresh air: FIFI F7 ePM1 55 mini-pleat filters%.
Resumption
stale air: FIFI M5 ePM10 50 pleated filters%.

Available as an option: Blowing fresh air: FIGR G4 Coarse 70 pleated filter% + FIFI F7 ePM1 55 minifold filter%,
FIFI M5 ePM10 50 pleated filter% + FIFI F9 ePM1 80 minipleat filter%.
Resumption stale air: FIFI F7 ePM1 55 mini-pleat filter%
Échangeur à contre-courant Moteur ECM By-pass Batterie chaude ou froide
Débit ou pression régulés GTC modbus / BACnet Régulation Plug and Play OPTAIR® CTA
Logo-EUROVENT.jpg
Air-to-air plate heat exchanger produced by RECUTECH, a company participating in the Eurovent program. Certification for AAHE.





  • Double skin insulation 45 mm
  • With or without integrated battery
  • Freewheel jet fan
  • Low consumption ECM engine
  • Thermal efficiency up to 90%

Application

Air introduction and extraction with energy recovery.
Indoor or outdoor use with rain cover.


  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Available in September 2025

7 sizes: 06 (600 m3/h) / 14 (1,400 m3/h) / 18 (1,800 m3/h) / 25 (2,500 m3/h) / 33 (3,300 m3/h) / 42 (4,200 m3/h) / 58 (5,800 m3/h)
8 models according to types of integrated batteries:

Electric post-heating Reversible water Electric antifreeze
E
ED
EI
EDI
E2R
ED2R
E3R
ED3R

Vertical construction with in-line duct connection.
Right (R) or left (L) servitude in the direction of the blown air.
New integrated EVCO regulation specific to VIM . Communicating Modbus RTU on RS485 port or Modbus TCP/IP, BACnet IP, remote EPJcolor touch control.
Bypass 100% modulating.

Construction
  • Self-supporting structure in extruded aluminum profile, rounded corners.
  • 45 mm double skin panel in alloy steel (Zn - Al - Mg) ZM310 for environments with corrosiveness C4 medium durability or C5 low durability, insulation by injected polyurethane foam (42 kg/m3 – 0.0246W/mk) fire classification B-S2, d0 (M1).
  • Vertical construction with in-line connection by circular tappings equipped with sealing joints.
  • Galvanized steel frame for floor mounting.
  • Possibility of adapting the position of certain tappings on site.
  • Access to filters, exchanger, battery and fan from the side.
  • Ø1/2˝ purge for condensate drainage.

Interchange
  • High efficiency counter-flow aluminum plate heat exchanger. Thermal efficiency up to 90%.
  • Motorized bypass 100%, integrated into the unit on the fresh air network.
  • 230V single-phase 3-point servomotor controlled proportionally by adjusting the running time.

Motorization
  • Freewheel type fan with metal reaction (incombustible A1).
  • High efficiency ECM motor, 400V 50/60Hz on size 45, 230V 50/60Hz on other sizes.
  • Control by 0…10V signal.
  • CAD HR BASIC E/EI/EC 06: IP44 Class B,
  • CAD HR BASIC E/EI/EC 14 - 18 - 25 - 33: IP54 Class B.
  • CAD HR BASIC E/EI/EC 42 and 58: IP54 Class F.
  • Electronic thermal protection.

Filtration

Filters supplied as standard:

  • Fresh air blowing: FIFI F7 ePM1 55 mini-pleat filters%.
  • Stale air intake: FIFI M5 ePM10 50 pleated filters%.

Optional filters available:

  • Blowing fresh air:
    • FIGR G4 Coarse 70 pleated filter% + FIFI F7 ePM1 55 minifold filter%,
    • FIFI M5 ePM10 50 pleated filter% + FIFI F9 ePM1 80 minipleat filter%.
  • Stale air intake: FIFI F7 ePM1 55 mini-pleat filter%

EI post-heating electric battery
  • Connected to the regulation, it allows the temperature of the blown air to be regulated.
  • Equipped with safety thermostat with automatic reset (set point 55°C) and manual reset (set point 70°C).

ED antifreeze electric battery
  • Placed on the fresh air before the exchanger, prevents the risk of freezing on the exchanger.
  • Assembled, wired and controlled by the regulator.
  • Safety thermostat with automatic reset (set point 55°C) and manual reset (set point 70°C).

ER2R and ER3R reversible hot/cold water battery
  • 2-row (ER2R) or 3-row ER3R water battery.
  • Composed of copper tubes with aluminum fins on a galvanized steel frame.
  • Copper collector.
  • Threaded connecting tube.
  • Condensate outlet to be connected to a siphon when used in cold conditions.
  • 230V/24V 10VA power supply for power supply of 2V or 3V valve, CO2 probe, fresh air register servomotor...

Air treatment selection
CAD HR BASIC 06 / 14 / 18 / 25

CAD-HR-BASIC-V-06a25-dim.jpg


CAD HR BASIC 33 / 42 / 58


CAD-HR-BASIC-V-33a58-dim.jpg

Model

A

B

C

Ø or ØDxE

Weight (Kg)

CAD HR BASIC 06 V

1680

780 740 250 176

CAD HR BASIC 14 V

1980

960 910 315 260

CAD HR BASIC 18 V

2130 990 980 355 282

CAD HR BASIC 25 V

2420

1100 1150 400 380

CAD HR BASIC 33 V

2320

1550 1204 900X410 490

CAD HR BASIC 42 V

2800

1415 1400 1000X510 590

CAD HR BASIC 58 V

2800

1975 1400 1400X510 753

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Close Open Commercial documents

Commercial leaflet (FCOM)

X