JBRB ECOWATT® PR VCHV

Regulated C4 extraction boxes

Direct drive - Reaction - ECM

JBRB ECOWATT® PR VCHV View larger

JBRB ECOWATT® PR VCHV

Regulated C4 extraction boxes


Direct drive - Reaction - ECM

PIC-ERP-conforme-01.jpgErP compliant 2018
UVNR - Variable EC motor
PIC-Isolation-acoustique-01.jpgPIC-ATEC-HYGRO-CSTB-01.jpgECM motor
Acoustic insulationEasy maintenanceOPTAIR RT Conso

  • Low power ECM motor out of the air stream
  • High performance reaction wheel
  • Constant pressure operation COP
  • Conformity with Hygro technical notice
  • Multiple installation configurations
  • Easy maintenance
  • Single or three-phase

Application
Air extraction.
Indoor or outdoor installation.
Approved 400°C 1/2h category C4.
CMV in collective housing and tertiary premises.
Air return in tertiary premises.
  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow rates from 100 to 9200 m3/h.
10 sizes: 04 / 06 / 10 / 22 / 30 / 38 / 48 / 70 / 82 / 92.
Available configurations:
  • L: online.
  • M: modular, supplied with a cap for 1 or 2 90° suctions.
  • D: 180° double suction.
Horizontal or vertical rejection version.
Insulated version: acoustic insulation with 25 mm glass wool (fire classification M0) in double-skin panels.


Options - Anti-corrosion treatment


JBRB ECOWATT VCHV - Main spare parts - Sizes 04 to 22


JBRB ECOWATT PR VCHV - Main spare parts - Sizes 30 to 92


Construction
  • ZM310 alloy steel sheet casing (Zn - Al - Mg) for environments with C4 medium durability or C5 low durability corrosivity, equipped with 4 fixing lugs (size 04 to 38) or 2 transverse omegas (sizes 48 to 92).
  • Lifting by 2 steel legs or by slinging through the omegas.
  • Connection tap with class D seals. Vertical discharge version supplied without connection tap (flat tap with PAPV seal to be mounted as an option with self-drilling screws).
  • Direct coupling.
  • INTZ : mounted/wired padlockable proximity switch.
  • BDEZ : pressure switch mounted, air-connected, factory set to 80 Pa.
  • High performance reaction turbine in galvanized steel.
  • Cover equipped with 2 or 4 handles, removable without tools to ensure easy access to the inside of the box for cleaning.
  • Horizontal or vertical rejection version.
  • IS version : Acoustic insulation with 25 mm A2-s1, d0 (M0) glass wool in double-skin panels.
  • Corrosion resistance treatment option: contact us.

Motorization
  • Electronically Commutated Motor ECM out of the airflow:
    • 04 to 22: IP44 class B single-phase 230V, 50Hz.
    • 30, 38, 48, 70, 82: IP54, class F, single-phase 230V, 50Hz.
    • 30, 38, 48, 70, 92: IP 54, class F, three-phase 400V, 50Hz.
  • Electronically controlled thermal protection approved for C4 operation.

VCHV Regulation
  • COP constant pressure operation.
  • Control box, IP54, factory mounted and wired.
  • 4-digit display with setpoint adjustment keys: clear display of the pressure measurement and the setpoint.
JBRB ECOWATT® PR VCHV 04/06/10/22/30/38 - L / M
Horizontal discharge




--- Available only on the modular version "M"

ModelABB1C*D1EFGHIJWeight (kg)
JBRB ECOWATT® PR VCHV 0462752353332016056850215717515716122
JBRB ECOWATT® PR VCHV 0662752353332020056850215717515716122
JBRB ECOWATT® PR VCHV 1062756658342125056954420718520718626
JBRB ECOWATT® PR VCHV 2276768370151135570966125223725223945
JBRB ECOWATT® PR VCHV 30101982087356840089279726727126727164
JBRB ECOWATT® PR VCHV 381153938971631500103690730633130633178

* IS version: +27 mm


JBRB ECOWATT® PR VCHV 48/70/82/92 - L / M
Horizontal discharge



--- Available only on the modular version "M"


ModelABB1C*D1EFGHIJWeight (kg)
JBRB ECOWATT® PR VCHV 4811659851065800560700918433330433330107
JBRB ECOWATT® PR VCHV 70128010301100880630815970473365473365121
JBRB ECOWATT® PR VCHV 821404110011759707108461032518405518405170
JBRB ECOWATT® PR VCHV 921404110011759707108461032518405518405170

* IS version: +27 mm


JBRB ECOWATT® PR VCHV 04/06/10/22/30/38 - L / M
Vertical discharge



--- Available only on the modular version "M"

ModelABB1C*D1EFGHIJWeight (kg)
JBRB ECOWATT® PR VCHV 0464852353332016056850215717513016522
JBRB ECOWATT® PR VCHV 0664852353332020056850215717513016522
JBRB ECOWATT® PR VCHV 1064856658342125056954420718516619826
JBRB ECOWATT® PR VCHV 2278968370151135570966125223723627145
JBRB ECOWATT® PR VCHV 30101982087356540089279726727124828664
JBRB ECOWATT® PR VCHV 381153938971637500103690730633131535078

* IS version: +27 mm



JBRB ECOWATT® PR VCHV 48/70/82/92 - L / M
Vertical discharge




--- Available only on the modular version "M"

ModelABB1C*D1EFGHIJWeight (kg)
JBRB ECOWATT® PR VCHV 4811199851065800560700918433330320340107
JBRB ECOWATT® PR VCHV 70123410301100880630815970473365370375121
JBRB ECOWATT® PR VCHV 821358110011759707108461032518405482415170
JBRB ECOWATT® PR VCHV 921358110011759707108461032518405482415170

* IS version: +27 mm


JBRB ECOWATT® PR VCHV 10/22/30/38 - D
Horizontal discharge




ModelABC*D1D2EFGHIJWeight (kg)
JBRB ECOWATT® PR VCHV 1081560342125020077754419416120718628
JBRB ECOWATT® PR VCHV 22104872051135531599866123921925223945
JBRB ECOWATT® PR VCHV 301324930566400355123879726724726727167
JBRB ECOWATT® PR VCHV 3814681024631500400139690830628130633183

* IS version: +27 mm



JBRB ECOWATT® PR VCHV 48/70/82/92 - D
Horizontal discharge



ModelABC*D1D2EFGHIJWeight (kg)
JBRB ECOWATT PR VCHV 4814901105800560450990918433270433330135
JBRB ECOWATT PR VCHV 7016911183880630500986978473301473365150
JBRB ECOWATT PR VCHV 821813123797071056010161032518340518405200
JBRB ECOWATT PR VCHV 921813123797071056010161032518340518405200

* IS version: +27 mm



JBRB ECOWATT® PR VCHV 10/22/30/38 - D
Vertical discharge



ModelABC*D1 **D2EFGHWeight (kg)
JBRB ECOWATT PR VCHV 1080460342125020077754419416128
JBRB ECOWATT PR VCHV 22103772051135531599866123921945
JBRB ECOWATT PR VCHV 301276930566400355123879726724767
JBRB ECOWATT PR VCHV 3814261025637500400139690930628183

* IS version: +27 mm - ** If adding a PAPV flat nozzle to connect the discharge



JBRB ECOWATT® PR VCHV 48/70/82/92 - D
Vertical discharge



ModelABC*D1 **D2EFGHWeight (kg)
JBRB ECOWATT PR VCHV 4814441105800560450990918433270135
JBRB ECOWATT PR VCHV 7016971183880630500986978473301150
JBRB ECOWATT PR VCHV 821767123797071056010161032518340200
JBRB ECOWATT PR VCHV 921767123797071056010161032518340200

* IS version: +27 mm - ** If adding a PAPV flat nozzle to connect the discharge

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other

Installation instructions (NT) Other languages

Close Open Performance / Environment Certificates

Close Open Prescription assistance

X