PURECLASS

Double flow air handling unit H with exchanger

Counter-current - Single zone - ECM < 1,000 m3/h

Flag Nouveau
PURECLASS View larger

PURECLASS

Double flow air handling unit H with exchanger


Counter-current - Single zone - ECM < 1,000 m3/h

Conforme ErP 2018 - UVNR - Moteurs EC variablesErP 2018 - UVNR compliant
Variable EC motors
Filters
Delivered as standard: Reprise stale air: FIFI M5 ePM10 50 pleated filters%. Blowing fresh air: FIFI F7 ePM1 55 minifold filters%, FIGR G4 Coarse 70 pleated filters%.

In accessories:
Blowing fresh air: FIFI F9 ePM1 80 mini-ply filters%, FIFI M5 ePM10 50 pleated filters%.
Échangeur à contre-courantMoteur ECMBy-pass
Débit réguléGTC ModbusRégulation Plug and PlayEASYVENT
Logo-EUROVENT.jpg
Air-air plate exchangers produced by the company RECUTECH which participates in the Eurovent Certification program for AAHE.




  • Modern design
  • Bypass 100% for freecooling
  • Antifreeze protection by modulating by-pass or antifreeze battery
  • Integrated electric coil or post-heating hot water
  • Low noise level
  • Thermal efficiency up to 90%

Application

Introduction and extraction of air with energy recovery in each room.
Installation suspended from the ceiling, wall-mounted or semi-recessed.
New or renovated: classrooms, shops, meeting rooms, medical offices, etc.

Watch the installation tutorial

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

1 size up to 1,000 m³/h.
12 standard models depending on internal batteries and integration of a CO2 probe

KindBattery type or QAI probe
Without batteryElectric post-heatingPost-heating hot waterElectric antifreeze exchangerIntegrated CO2 probe
NC
PH
DI
DC
PH DI
PH DC
NC CO2
PH CO2
DI CO2
DC CO2
PH DI CO2
PH DC CO2

Horizontal connection diameter 315
ADVANCED communicating regulation Modbus RTU-RS485
ETD PURECLASS remote control as a mandatory accessory that can control up to 5 units in a network
CAV constant flow or VAV variable flow operation

Construction
  • Self-supporting structure box interior finish in galvanized steel.
  • Exterior finish in white painted aluminum, RAL 9003.
  • Interior thermoacoustic insulation in melamine foam, density 9.5 kg/m³, M1 classification.
  • Perforated sheet metal at the outlet below the device serving as access hatches to the extraction filters.
  • Diffusion grille in the lower part of the front face, black RAL 9011 color.
  • Access to fresh air filters and fans via hinged doors at the bottom of the unit.
  • Condensate collection tray equipped with a condensate drain pump (factory connected) and a quick connector for Ø8 mm drain pipe.
  • Single action inlet fan.
  • Low consumption ECM motor, direct current, single phase 230V. Electronic thermal protection - manual reset

Register and non-return valve
  • Motorized damper on the fresh air inlet, mounted, wired, controlled by the regulation, with non-return valve on extraction to prevent air inlets when the unit is stopped.

Interchange
  • High-efficiency air/air counter-current exchanger made of aluminum, operating temperature up to 80°C. Thermal efficiency up to 90%.
  • Antifreeze protection of the exchanger integrated into the regulation by progressive opening of the by-pass or proportional control of an electric antifreeze battery
  • Bypass 100% equipped with a proportional motor.

Filtration

Integrated as standard

SideFilteredKindDimensions
ISO-16890EN-779LengthWidthThickness
Fresh airFIGR G4 Coarse 70% 365X441X48 mm
Pleated filter
ISO Coarse 70%G444136548
FIFI F7 ePM1 55% 365X441X48 mm
Mini-pleat filter
ePM1 55%F744136548
ResumptionFIFI M5 ePM10 50% 1104X158X48 mm
Pleated filter
ePM10 50%M51104*15848

*extraction filter supplied in 2 parts of 552 mm.

In accessories

SideFilteredKindDimensions
ISO-16890EN-779LengthWidthThickness
Fresh airFIFI M5 ePM10 50% 365X441X48 mm
Pleated filter
ePM10 50%M544136548
Fresh airFIFI F9 ePM1 80% 365X441X48 mm Mini-pleat filterePM1 80%F944136548


Built-in antifreeze electric battery (PH)
  • Power 2Kw Mono 230V.
  • Delivered fully pre-wired and connected to the control.
  • Power regulated proportionally.
  • Thermal protection with automatic reset (60°C) and manual reset (85°C).

Integrated electric post-heating battery (DI)
  • Power 3Kw Mono 230V or 1.5kW if antifreeze battery.
  • Delivered fully pre-wired and connected to the control.
  • Power regulated proportionally.
  • Thermal protection with automatic reset (60°C) and manual reset (85°C).

Integrated hot water battery (DC)
  • Battery made of copper tube and aluminum fin.
  • Antifreeze protection probe on the water return.
  • 3-way motorized valve proportional by 0-10V signal (accessory).

ADVANCED regulation ready to plug in
  • Complete regulation allowing 2 operating modes:
Flow rate adjustmentRecommended applications
VAV mode - Variable flow
Fan speed variation by 0-10V signal
- Flow rate setpoint value based on a 0-10 V signal from the remote control or an external probe (CO2, temperature, humidity, etc.).
Single-zone installations, requiring ventilation adaptation depending on occupancy.
CAV Mode - Constant Flow
Fan speeds set to a specific flow rate
- 3 maximum constant flow rate settings, entry of values with reading on display.
- Switching between the different settings carried out manually from the remote control or automatically by clock or presence detection.
Installations requiring control of one or more specific flow rates.
  • Programmable regulation from the remote control.
PURECLASS - NC - PH - DI - PH DI - PH CO2 - DI CO2 - PH DI CO2

PURECLASS-NC-PHDI-PHCO2-DICO2-PHDICO2.pn

ModelWeight (kg)
PURECLASS 800 CL NC152
PURECLASS 800 CL DI158
PURECLASS 800 CL PH157
PURECLASS 800 CL PH DI163


PURECLASS DC - PH DC - DC CO2 - PH DC CO2

PURECLASS-DC-PHDC-DCCO2-PHDCCO2.png

ModelWeight (kg)
PURECLASS 800 CL NC152
PURECLASS 800 CL DC157
PURECLASS 800 CL PH DC162

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Close Open Installation instructions

Installation instructions (NT)

Close Open Performance / Environment Certificates

Close Open Prescription assistance

Specification text (TP)

ENGINAIR
Selection of CAD O INTEGRAL, PURECLASS, CAD HR SLIM Media locked

For any questions, please send an email to optair@vim.fr

AIR TREATMENT
Dual-flow CTA selection
  • Sizing and price quote
  • Calculating the efficiency of the heat exchanger
  • Engine fuel consumption
  • Selection of accessories
  • Battery characteristics