KUBAIR® F400 CC/MV

F400 120 extraction boxes

Direct drive - reaction < 23000 m3/h

KUBAIR F400 MV View larger

KUBAIR® F400 CC/MV

F400 120 extraction boxes


Direct drive - reaction < 23000 m3/h

Conforme ErP 2018 ErP - UVNR ErP 2018 compliant - UVNR
Agréé 400°C 2h Conformité Européenne Isolation acoustique
Maintenance facilitée Coffret relayage Monté/Câblé OPTAIR® Ventilation, EASYVENT, OPTAIR® VVTP

  • High-performance reaction turbine
  • Approved F400 120 with relay box
  • Multi-directional connection
  • Easy maintenance and cleaning
  • Waterproof kitchen version
  • KUBZ 10 manual flow adjustment device

Application

Extraction of fumes and hot gases in the event of fire.
Extraction of stale air from tertiary and industrial premises.
Extraction of pollutants in professional kitchens.
Maximum temperature of extracted air in steady state: 120°C.
Installation in all positions and connection on all sides, except with vertical motor axis and motor at the bottom.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow rates from 500 to 23,000 m3/h.
10 sizes: 355 / 400 / 450 / 500 / 560 / 600 / 630 / 670 / 710 / 800.
KUBAIR® F400 CC: complete unit with multi-directional suction plenum, horizontal or vertical axis motor.
KUBAIR® F400 MV: ventilation unit only, horizontal or vertical axis motor.

Options - Anti-corrosion treatment


KUBAIR F400 - Main spare parts


Construction
  • Interchangeable galvanized steel sheet panels.
  • Modular structure in aluminum profiles.
  • 4 fixing legs.
  • Connection by 2 smooth KUBZ12 flanges included, interchangeable.
  • Galvanized steel reaction turbine, mounted in direct coupling with the engine.
  • Access to the interior for cleaning and maintenance without uncoupling the housing.

Motorization
  • AC motor, class H, optional PTO thermal protection:
    • 1 speed single phase 230V, 50Hz, IP55, 4 or 6 poles.
    • Accepts speed variation by voltage variator, or by single-phase/single-phase frequency variator (VFIK Mono/mono).
  • AC B5 motor, class F, optional PTO thermal protection outside the air flow:
    • Three-phase 230/400V 50Hz 1 speed 4-6-8 poles IE2 or IE3 accepts speed variation by frequency variator.
    • Three-phase 400V 50Hz 2 speeds, 4/6, 4/8, 6/8 or 6/12 poles, Dahlander or independent windings.

Factory-fitted and approved F400 120 electrical equipment
  • INTZ : padlockable proximity switch with 2 auxiliary contacts (1 NO and 1 NC).
  • BDEZ : 20-300 Pa pressure switch fitted, not air-connected, to be adjusted on site.
  • Single-phase/single-phase frequency inverter:
    • Linearly controls the speed of a 230V single-phase 1-speed asynchronous motor from 15Hz to 50Hz.
    • Single-phase 230V 50/60Hz inverter power supply, single-phase 230V 50Hz output.
    • Available in IP20 or IP66 version.
    • Caliber 7A.
  • PILOTAIR® : relay box
    For certain calibers, the box can be supplied mounted wired on the engine hood, protected by a visor
    For all calibers it can be supplied as an accessory or simply wired.

F400 120 Approved Installation Accessories
  • KUBZ 14 - Kitchen option
    • Reinforced sealing with grease resistant gasket.
    • Drain purge supplied not fitted.
    • Double skin not insulated.
  • KUBZ 09 - Double skin insulated 25 mm rock wool M0.
  • KUBZ 10 - Manual flow adjustment shutter
    • Positioned at the discharge. Allows the flow rate to be reduced (between 5% and 30%) and adjust the operating point.
  • KUBZ 16 - Pressure relief flap to be mounted on the discharge
    Ensures good water and air tightness when the box is stopped.
    Accessory for horizontal shaft motor housing.
  • KUBZ 17 - Pressure relief flap to be mounted on the discharge
    Ensures good water and air tightness when the box is stopped.
    Accessory for vertical shaft motor housing. F400 120 approved.

Smoke extraction fan selection
MV version
Assembly with horizontal motor axis
KUBAIR-F400-MV-H-dim

MV version
Assembly with vertical motor shaft
KUBAIR-F400-MV-V-dim.png

CC version
Assembly with horizontal motor axis
KUBAIR-F400-ECOWATT-CC-H-dim

CC version
Assembly with vertical motor shaft
KUBAIR-F400-CC-V-dim

Taille A BH BV BVC C D E EC
355 627 695 327 645 263 559 606 790
400 699 767 361 678 297 631 606 864
450 779 847 392 738 326 711 606 990
500 858 925 424 784 338 768 700 1039
560 954 1021 441 817 354 864 700 1139
600/630 1066 1133 488 912 403 977 700 1183
670/710 1194 1261 551 1032 462 1104 906 1325
800 1338 1420 574 1084 488 1248 906 1379

Taille F G GC H J K KC L
355 660 31 50 315 102 677 954 321
400 732 31 50 349 102 711 1022 321
450 812 31 50 378 102 743 1081 321
500 890 42 62 402 112 805 1145 351
560 986 42 62 419 112 822 1178 351
600/630 1098 42 62 466 112 869 1273 351
670/710 1226 42 62 526 112 994 1488 446
800 1370 42 62 552 127 1050 1540 446

Close Open Detailed specifications

Text catalog pages (CT)

Text catalog pages (CT) Other languages

Close Open Public tariff price

Price catalog pages (CP)

Close Open Fire / Smoke extraction certificates

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

EASYVENT
Access the software online Media locked
ALL APPLICATIONS
LOGO_EASYVENT-WEB-bord-blanc.jpg Selection of fans and AHU
  • Creation of complete technical sheets with thermal data (CTA), fan operating points, acoustic characteristics and dimensional drawings.
Other products: permanent updates
BSP F400
CAB ECOWATT
CAD HR SLIM
CAD O INTEGRAL
CBM
CBM RE
CGT
CAT N F400
CHGT F400 - CHGT F300
CHRB/TN - CRVB/TN
CMB - CMT
CRHB-CRVB ECOWATT
CTB
CVAB N - CVAT N
CVAB N - CVAT N ECOWATT
FR F400
HCTB - HCTT - HCTT ATEX
HDB ATEX
HGHT F400 / F200
HGTT-V
HXBR - HXTR
HXBR ECOWATT
KABB - KABT
PURECLASS
TCBB - TCBT
TCTB ATEX - TGT ATEX
TCDH ATEX
TD - TD ECOWATT
TD ATEX
TD SILENT - TD SILENT ECOWATT
TGHT F400 - THGT F200
TGT
TGT ATEX
THC - THC ECOWATT
THGT HATCH F400
TRB - TREB
TXBR ECOWATT
ECOWATT WIND
VENT-NK - VENT-VN


OPTAIR Ventilation
Download OPTAIR Ventilation Media locked
VMC SMOKE EXHAUST
OPTAIR-Ventilation.png Selection of turrets and boxes: KDT / KSH / TCD / KUBAIR / TED
  • VScreation of a technical sheet per fan including the requested operating point on the curve, the technical and acoustic characteristics, and the overall dimensions
  • Printing possibility
  • Link to all technical pages Catalog
KCTR F400
KDTA BP
KDTA F400
KDTR BP
KDTR F400
KSHA
KSHP
KSHR
KUBAIR F400 CC
KUBAIR F400 ECOWATT CC
KUBAIR F400 ECOWATT MV
KUBAIR F400 MV
TCDH F400
TCDV F400
TEDH F400
TEDH F400 ECOWATT
TEDV F400
TEDV F400 ECOWATT
OPTAIR VVTP
Download OPTAIR VVTP Media locked
For any operating problems, please send your request by email to optair@vim.fr
VMC SMOKE EXHAUST
OPTAIR-VVTP.png

Flow calculation Ventilation of a Protected Technical Volume

  • Calculation based on the smoke extraction flow rate, the installed extractor, the duct network and the characteristics of the room.
  • Facilitates the optimization of flow rates by adjusting the different parameters
  • Selection of air intake grilles or shutters.
  • Summary technical sheets.
Fans

Grids
X