TEDH C4 ECOWATT® - TEDV C4 ECOWATT®

Unregulated C4 roof fans

Centrifugal - Backward - ECM < 1000m3/h

TEDV C4 ECOWATT® View larger

TEDH C4 ECOWATT® - TEDV C4 ECOWATT®

Unregulated C4 roof fans


Centrifugal - Backward - ECM < 1000m3/h

PIC-ERP-conforme-01.jpg ErP 2018 compliant - UVNR - Variable EC motor
PIC-Isolation-acoustique-01.jpg PIC-ATEC-HYGRO-CSTB-01.jpg OPTAIR RT Conso

  • Low consumption ECM motor
  • Integrated potentiometer
  • 400 ° C 1 / 2h category 4 approved
  • High performance reaction wheel
  • Compliance Hygro technical advice

Applications:

Air extraction.
Outdoor installation.
400 ° C 1 / 2h category 4 approved.
CMV in collective housing and tertiary premises.
Air intake in tertiary premises.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow: 200 to 1000 m3/ h.
Size: 225.
With INTZ or with INTZ + BDEZ.
TEDH C4 ECOWATT® : horizontal discharge.
TEDV C4 ECOWATT® : vertical discharge.

OPTIONS - CORROSION PROTECTION


  • High performance galvanized steel backward turbine.
  • Optimized suction lodge.
  • Direct coupling on the motor shaft.
  • Z275 galvanized steel plate, arm and motor support.
  • 4 lifting legs.
  • Arm covers and protective grilles in RAL 7024 gray pre-painted sheet metal.
  • Meshes conforming to standard NF EN ISO 12499.
  • Shell in RAL 7024 gray PMMA ABS.
  • Vertical discharge version: addition of 3 pre-lacquered RAL 7024 sheet deflectors delivered factory fitted.
  • INTZ: padlockable proximity switch with position feedback.
  • BDEZ: pressure switch fitted, aeraulic connection, factory set at 80 Pa.

Motorization:
  • Electronic Commutated Motor (ECM):
    • IP 44, class B single phase, 230V 50Hz.
  • Thermal protection managed by electronics.

Particular case of the use in collective CMV when the air extraction of the same dwelling is carried out by several extractors. The extractors must be able to work only simultaneously: imperative use of the BAHV box to control the turrets of a same dwelling. The installation can be completed by a box of alarm report in order to know the state of functioning of the CMV: box BRVH.

BAVH box:

  • White metal case, vandal-proof.
  • Positive safety anti-siphoning safety control unit (manual reset): article 10 Order of 24 March 1982 amended.
  • Control of up to 6 turrets serving vertical conduits corresponding to the same stack of dwellings.
  • Allows all turrets in the same stack to be stopped in the event of a fault in one of them.
  • Can only serve one stairwell.
  • Power supply of each turret: Pmax: 170 W; Imax: 1.5 A per turret.
  • Power supply to the box: single-phase 230V, 50-60Hz.
  • Slaves the BRVH alarm report box.
  • Note: Provide a TEDH / TEDV C4 ECOWATT equipped with a BDEZ pressure switch.

BRVH box:

  • White metal case.
  • Alarm report box: correct operation of the installation, ventilation fault in one or more turrets.
  • Remote installation in common areas to warn of the operating status of the ventilation.
  • Contains two indicator lights:
    • Red diode: ventilation fault,
    • Green LED: voltage present.
  • Power supply by the BAVH box.
  • Audible alarm function activated by key.

Fan selection C4 - 400 ° C 1 / 2H
TEDH C4 ECOWATT®
TEDH-C4-ECOWATT-dim.png

Model

A

B

CH

D

E

F

Weight (Kg)

255

430

437

567

185

344

30

18




TEDV C4 ECOWATT®
TEDV-ECO-dim.png

Model

A

B

CV

D

E

F

Weight (Kg)

255

430

437

663

185

344

30

19

Close Open Detailed specifications

Text catalog pages (CT)

Catalog Pages - Other

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Commercial documents

OPTAIR RT Conso
Download OPTAIR Conso Media locked
COLLECTIVE AND TERTIARY VMC
OPTAIR-RT-Conso.png Calculation of VMC flow rates

Selection of VMC boxes
  • Automatic calculation of min/max flow rates DTU 68.3 and RT2012
  • Selection of suitable fans
  • Detailed technical sheet with fan consumption determined according to its operating point, following Th-BCE rules
  • Automatic app update (requires internet connection)
ALIZE AUTO
ALIZE HYGRO
JBEB MV
JBHB ECO ECM PR
JBRB ECOWATT
JBRB ECOWATT PR
JBRB ECOWATT PM
JBRE AC (bientôt disponible)
JBRE ECOWATT
JBRE ECOWATT PR
KMDT - KMDT PM
KSTD
KSTD ECOWATT
KSTD IP
KUBAIR F400 ECOWATT MV
TCRH TCRV ECOWATT
TCRH TCRV ECOWATT PR
TCSH
TCSH ECOWATT
TECH C4 ECOWATT (bientôt disponible)
TEDH TEDV C4 ECOWATT
TEDH TEDV C4 ECOWATT PR
TEDH TEDV F400 ECOWATT
THERMOGAZ

OPTAIR VMC
Download OPTAIR VMC Media locked
COLLECTIVE AND TERTIARY VMC
OPTAIR-VMC.png Sizing of VMC installations

Material list and quote
  • Network sizing and selection of the appropriate fan.
  • Works for any self-adjusting, hygro-adjustable and gas installation.
  • Calculations in accordance with current standards.
  • Provides a detailed and costed list of selected hardware.
  • Allows quotes to be produced from the VIM product database.
  • Possible application in TERTIARY single-flow VMC.
ALIZE AUTO
ALIZE HYGRO
JBEB MV
JBHB ECO ECM PR
JBRB ECOWATT
JBRB ECOWATT PR
JBRB ECOWATT PM
JBRE AC (bientôt disponible)
JBRE ECOWATT
JBRE ECOWATT PR
KMDT - KMDT PM
KSTD
KSTD ECOWATT
KSTD IP
KUBAIR F400 ECOWATT MV
TCRH TCRV ECOWATT
TCRH TCRV ECOWATT PR
TCSH
TCSH ECOWATT
TECH C4 ECOWATT (coming soon)
TEDH TEDV C4 ECOWATT
TEDH TEDV C4 ECOWATT PR
TEDH TEDV F400 ECOWATT
THERMOGAZ
X