DLFF B

Linear diffusers

Fixed slots

DLFF-B View larger

DLFF B

Linear diffusers


Fixed slots

  • Low noise level
  • Adapted to variable flow rate
  • Model for 600 x 600 or 600 x 1200 mm slab
  • RAL 9003 matt white finish

Application

Air conditioning, heating, ventilation.
Horizontal blowing.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

8 models from 1 to 4 slots, lengths 300, 544 (slab), 600, 900, 1144 (slab), 1200 mm.

Description
  • Linear diffuser with fixed slots.
  • Diffuser in extruded aluminum painted in matt white RAL 9003.
  • Profiles specifically designed to ensure a stable vein.
  • Reduced pressure loss and noise level.
  • Allows variable flow operation.
  • Friction clip attachment to the plenum, and grille retaining cable.
  • Plenum made of galvanized steel, bare or insulated with 6mm of light gray M1(B-s1,d0) melamine foam on 5 sides, with or without perforated register in the tapping.
  • Other RAL: contact us.
Blowing directions



DLFF


PDFF


1 SLOT2 SLOTS
L3005446009001144120030054460090011441200
B60.660.660.660.660.660.692.692.692.692.692.692.6
W484848484848808080808080
T82.582.582.510012012082.5100100120145145
HAS60.560.560.560.560.560.560.560.560.560.580.580.5
H300300300300300300300300300300325325
Ø123123123158198198123158158198248248
3 SLOTS4 SLOTS
L3005446009001144120030054460090011441200
B124.6124.6124.6124.6124.6124.6156.6156.6156.6156.6156.6156.6
W112112112112112112144144144144144144
T100120120145145145120145145145145145
HAS60.560.560.580.580.580.580.580.580.580.580.580.5
H300300300325325325300325325325325325
Ø158198198248248248198248248248248248

All dimensions in mm. Cut-out to be provided in the ceiling = (L+25) x (W+3)

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Technical data (DTEC)

FACT Air Diffusion
Media locked

BROADCASTING
Fact.pngSelection of GRADA grilles and diffusers
  • Modeling of the air flow in a room as a function of supply temperature and ambient temperature in summer or winter.
  • Allows you to visualize the air speed profile in the comfort zone (H
  • Allows you to determine the range, noise level and pressure drop of the selected terminal for a given flow rate.
  • Creation of a comprehensive report on the results obtained.
GRADA designation
MSH01
DA340
CC600
DS170/DR170
DC560
WS230/WS230P
WS400
WR230
HD600
EG400PF/EG400-F
CS400
TS600
TE370
TE750
AD130-F/GD130-F
AD100-F/GD100-F
SF130
AD600
BD640
AG300/AG320
JD130/JD120/JD110
JD170/JD160/JD150
SLF
SLS
CB400
VIM designation
DABR GD
DATI
DCDU
DCFD/DCFS
DDTI
DJHC/DJHD
DJHE
DJHR
DLFF B
DPCD/DPCS AB
DPDU
DPFF A PH/PHI
DPSR 2D/2DI
DPSR 4D/4DI
GADD A/GADD F
GASD A/GASD F
GCDD FG
GLBF
GLBF AF
GSBF A/GSBF AI
JDLP C/F/G
JDSP C/F/G
SLF
SLS
GCBI
X