SLF

Linear diffusers

With adjustable slots - Filter holder

SLF View larger

SLF

Linear diffusers


With adjustable slots - Filter holder

  • Tilting core
  • Adapted to variable flow rate
  • Significant diffusion capacity
  • Ceiling or wall mounting
  • Horizontal or vertical diffusion
  • Painted aluminum finish RAL 9010, 9016, 9003 matt
  • Models on plates for standard or fine line 5/8 slabs
  • Combined plenum for supply and return

Application

Air conditioning, heating, ventilation.
Horizontal or vertical diffusion.
Airflow adjustable up to 180°.
Ceiling or wall mounting.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

  • Blowing or extraction diffusers with 2, 3, 4, 5 or 6 slot deflectors.
  • Finishes:
    • Diffuser white RAL 9010 – deflector RAL 9010.
    • Diffuser white RAL 9016 – deflector RAL 9016 matt.
    • Diffuser white RAL 9003 matt – deflector RAL 9003 matt.
  • Other RAL: contact us.
  • Available without baffle for use in extraction.
Standard diffuser: SLF
  • One-piece diffuser, minimum length 300 mm, maximum 1500 mm.
  • 20mm finishing frame.
  • Length for integration of 600 x 600 slab: 554 mm.
  • Length for integration of 1200 x 600 slab: 1154 mm.
Diffusers on plate for false ceiling tiles: SLF P / SLF Z / SLF Q / SLF Y

SLF PSLF Z
Plate width 300, 594 or 669 mm
4 raised edges of 10 mm

Plate width 300, 594 or 669 mm
2 fine-line edges 5/8 on the short side
2 raised edges of 10 mm on the long side

SLF QSLF Y
Square plate width 594 or 669 mm
4 raised edges of 10 mm

Square plate width 594 or 669 mm
4 fine-line edges 5/8




Diffusers
  • SLF
    • Diffusers made of extruded aluminum coated with RAL powder.
    • Extruded aluminum deflectors powder coated RAL.
    • 20 mm frame.
    • Slot width 25 mm.
    • Fixed fixing by screws on the plenum.
  • SLF P / SLF Z / SLF Q / SLF Y
    • Painted aluminum diffusers integrated into a RAL powder-coated steel sheet plate identical to the diffuser.
  • Plenum: SPF
    • Plenum for fixed mounting on SLF diffusers.
    • Length = Slot length + 30 mm.
    • Naked or isolated.
    • Made of Z275 galvanized steel.
    • Class D waterproof tapping with double lip seal in PP+TPE.
    • Direct mounting with screws on the diffuser.
    • Optional 6 mm melamine insulation.
  • Plenum: SPF SR
    • Combined supply and return plenum for fixed mounting on SLF diffusers.
    • Length = Slot length + 30 mm.
    • Naked or isolated.
    • Made of Z275 galvanized steel.
    • Class D waterproof tapping with double lip seal in PP+TPE.
    • Direct mounting with screws on the diffuser.
    • Optional 6 mm melamine insulation.
  • FIGR Filter
    • G3 Coarse 70 Filter Panel%, fan coil type, 4mm thick.
    • Galvanized steel wire frame, media-sewn.
    • Installation at an angle inside the plenum, and locking with a 1/4 turn.
Standard diffuser
SLF


SLF-dim

L = diffuser slot length
Reservation = L+30 x A-12


SLF + SPF plenum


Plate diffusers
SLF P / SLF Z / SLF Q / SLF Y




Diffuser on plate + SPF plenum



LandmarkNumber of slots / dimensions (mm)
23456
A121164207252295
C5858587878
ØD158198198248248
E93136179223267
FiL x 208L x 272L x 296L x 363L x 390
H281321321371371
H1181201201226226
W94137180225268

L ≤ 1200: 1 tapping; L ≥ 1201: 2 tappings
G = 300, 594 or 669 depending on the type of plate


SPF SR Plenum


L (mm)L1 (mm) blowingL2 (mm) recovery
1000500500
1100550550
1134584550
1154604550
1200600600
1284684600
1300650650
1400700700
1500750750


Diffusers on plate + plenum
Fixed mounting



Plate typePlate width GPlate length L2Slot length L
P4 folded edges 10 mm300594532
669600
11941134
13441284
59411941134
66913441284
Z2 fine line edges + 2 folded edges 10 mm300594532
669600
11941134
13441284
59411941134
66913441284
Q4 folded edges 10 mm594594532
669669600
Y4 fine line edges 5/8594594532
669669600

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Prescription assistance

Specification text (TP)

FACT Air Diffusion
Media locked

BROADCASTING
Fact.pngSelection of GRADA grilles and diffusers
  • Modeling of the air flow in a room as a function of supply temperature and ambient temperature in summer or winter.
  • Allows you to visualize the air speed profile in the comfort zone (H
  • Allows you to determine the range, noise level and pressure drop of the selected terminal for a given flow rate.
  • Creation of a comprehensive report on the results obtained.
GRADA designation
MSH01
DA340
CC600
DS170/DR170
DC560
WS230/WS230P
WS400
WR230
HD600
EG400PF/EG400-F
CS400
TS600
TE370
TE750
AD130-F/GD130-F
AD100-F/GD100-F
SF130
AD600
BD640
AG300/AG320
JD130/JD120/JD110
JD170/JD160/JD150
SLF
SLS
CB400
VIM designation
DABR GD
DATI
DCDU
DCFD/DCFS
DDTI
DJHC/DJHD
DJHE
DJHR
DLFF B
DPCD/DPCS AB
DPDU
DPFF A PH/PHI
DPSR 2D/2DI
DPSR 4D/4DI
GADD A/GADD F
GASD A/GASD F
GCDD FG
GLBF
GLBF AF
GSBF A/GSBF AI
JDLP C/F/G
JDSP C/F/G
SLF
SLS
GCBI
X