KSTD IP

Extraction or insufflation boxes

Direct drive - Action - IP < 6500 m3/h

K STD IP View larger

KSTD IP

Extraction or insufflation boxes


Direct drive - Action - IP < 6500 m3/h

PIC-ERP-conforme-01.jpg K STD IP 16/38 - ErP 2018 compliant - UVNR with variable speed drive
K STD IP 35/60 - Not ErP compliant - For process ventilation
PIC-Isolation-acoustique-01.jpg PIC-Porte-filtre-01.jpg OPTAIR RT Conso

  • Watertight casing + drain
  • Metal filter
  • IP44 or IP55 motor with external rotor
  • Bare, double skin insulated 50 mm
  • Switch + Depressostat fitted


Application
  • Stale air extraction, for humid or charged air.
  • Installation indoors or outdoors.
  • Horizontal mounting.
  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flows from 400 to 6500 m3/h.
4 sizes: 16 / 35 / 38 / 60.
2 variants:
  • NU: casing without insulation.
  • DB: 50 mm reinforced rock wool insulation, 6 sides.
With INTZ or INTZ + BDEZ.

Construction
  • Casing made of Z275 galvanized sheet steel, fitted with 4 fixing lugs.
  • Access to the filter through the cover.
  • Circular connection fittings with class D seal.
  • Double inlet fan with integrated motor.
  • Bottom of the waterproof box to prevent drips.
  • Metallic knit filter.
  • Condensate and cleaning product drain.
  • INTZ: padlockable proximity switch with mounted/wired position feedback.
  • BDEZ: Fitted pressure switch, not connected to the aeraulics, to be adjusted on site.
  • DB version: double skin with reinforced, acoustic and thermal insulation in 50 mm rock wool, fire classification A2-s1, d0 or M0.

Motorization
  • Model 16: RE motor (External Rotor) IP44 single-phase asynchronous 230V, 50Hz, class F, 1 speed with built-in thermal protection with manual reset.
  • Models 35, 38: RE motor (External Rotor) IP55 single-phase asynchronous 230V, 50Hz, class F, 1 speed with built-in thermal protection with manual reset.
  • Model 60: RE motor (External Rotor) IP55 asynchronous three-phase 230/400V, 50Hz, class F, 1 speed with built-in thermal protection with manual reset.

Fan selection C4 - 400°C 1/2H

Version

Size

A

B

C

ØD

E

F

G

H

ØJ

K

Weight (kg)

INTZ

DIJZ

NU

16

450

450

426

355

226

534

474

50

9

95

120

18

35

600

600

504

450

258

754

623

50

9

95

120

36

38/60

702

702

656

500

382

853

724

50

9

95

120

53

DB

16

530

530

518

355

268

680

554

50

9

95

120

30

35

675

675

595

450

319

823

698

50

9

95

120

57

38/60

772

772

737

500

420

915

805

75

12

95

120

91

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation / maintenance manual (NT)

Installation / maintenance manual (NT) Other

Installation / maintenance manual (NT) Other languages

Close Open Performance / Environment Certificates

ErP regulatory sheet (FERP)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

OPTAIR RT Conso
Download OPTAIR Conso Media locked
Selection software for collective ventilation units - Calculation of electrical consumption
For any operating problem, please send your request by email to optair@vim.fr
RTConso-2018.jpg
  • Automatic calculation of minimum / maximum flow rates DTU 68.3 and RT2012
  • Selection of suitable fans
  • Detailed technical sheet with fan consumption determined according to its operating point, according to Th-BCE rules
  • Automatic update of the application (requires an internet connection)

March 2021: new version (automatic update)

  • In tertiary rapid calculation, possibility of selecting turrets / KUBAIR

  • Modification of ranges: HUCF ECO PR, TEDV / TEDH ECOWATT C4, JRBR ECOWATT / JRBR ECOWATT PR / JRBR ECOWATT PM (sizes 30 and 38), JRBR ECOWATT Sigfox / JRBR ECOWATT PR Sigfox / JRBR ECOWATT PM Sigfox (sizes 30 and 38) , KUBAIR ECOWATT (Mono)

  • Addition of the JBRE ECOWATT, JBRE ECOWATT PR ranges

Download user manual
OPTAIR VMC
Download OPTAIR VMC 2018 Media locked
VMC installation sizing and quotation software
For any operating problem, please send your request by email to optair@vim.fr

  • Network sizing and selection of the suitable fan.
  • Works for any self-adjusting, hygro-adjustable and gas installation.
  • Calculations in accordance with current standards.
  • Provides a detailed and costed list of the selected material.
  • Allows the production of quotes from the database of VIM products.
  • Possible application in TERTIARY single-flow CMV.

August 2020: new version (automatic update)

  • Addition of TED F400 ECOWATT COP and KUBAIR F400 ECOWATT COP (in rapid collective VMC project and in full project)
  • Addition of K STD and K STD IP 16
  • Removal of K STD and K STD IP 19
Download user manual


3 BRASSEURS

Close Open 3 BRASSEURS

Restaurant chains

59 - North

Close Open CUISINE CENTRALE CENTRE PSYCHOTHERAPIQUE - BOURG EN BRESSE

Central kitchen / Food industry

01 - Ain

Close Open HOTEL IMPERATOR

Hotels

30 - Gard

LYCEE PROFESSIONNEL - AUBIN

Close Open LYCEE PROFESSIONNEL - AUBIN

High schools

RESTAURANT PERRUCHE - PRINTEMPS HAUSSMANN

Close Open RESTAURANT PERRUCHE - PRINTEMPS HAUSSMANN

Independent commercial catering

75 - Paris

X