Diffusion basse vitesse OPTAIR® Cuisine

  • Improved comfort through low-speed diffusion
  • Rigid and hygienic design
  • Exposed faces in AISI 304L stainless steel with brushed SB finish
  • Height 400 and 500 mm
  • Constant height vertical sloping hood
  • Large retention volume
  • Cheeks without visible marks

Application

Capture and filtration of pollutants and heat.
Low speed air diffusion from the front face.
Ensures staff comfort and contributes to better capture efficiency.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Single leaning or double central.
Central hoods made by assembling back to back 2 hoods attached with partitions.
Single-block modules length 1000, 1500, 2000, 2500 and 3000 mm.
Depth advance: 1250, 1500 or 1750 mm.
Height: 400 and 500 mm.
Dimensions and finishes identical to the models: CHEF, FOUR, LAUNDRY and INDUCT from the VORAX Range®.


Hood
  • Constant height hood for maximum storage volume.
  • Allows the introduction of air at low speed through its front face thanks to a double perforation:
    • Flow rate up to 1200 m3/h/m linear for h=500 mm - ΔP=60 Pa.
    • Flow rate up to 960 m3/h/m linear for h=400 mm - ΔP=60 Pa.
  • Isolated pulse chamber equipped with a flow balancing and distribution device.
  • Pressure measurement.
  • Removable panel for access to the blow register and the pulsation chamber for periodic cleaning.
  • Self-supporting construction with no visible fixings or sharp edges for cleaning without the risk of cuts. Sides with no visible marks such as rivets and studs.
  • Lateral reinforcements, in 15/10 galvanized steelth height 50 mm, integrated into the hood, ensuring the rigidity of the assembly.
  • Leveling adjustment from inside the hood and clip-on fixing covers.
  • Gussets at the end of the sensor for a rigid junction between 2 modules while allowing a large air passage.
  • Exposed faces in austenitic stainless steel AISI 304L (1.4307) brushed SB finish. Rear and upper faces in galvanized steel.
  • Standard media filters galvanized stainless steel frame M0 397x472x25 mm.
  • Stainless steel shutter plate.
  • Peripheral gutter.
  • Stainless steel purge organ and cap - 1/2” Gas thread.

Packaging
  • Packed in a clear crate under heat-shrink film.
  • Stainless steel exterior faces protected by PVC film.
VORAX® CONFORT
Optional lighting - Delivered undrilled

Underlined = dimensions of model 400 - Not underlined = model 500



Module

Total length*

Capture length

Number of holes

A

B

D

P perforation dimension

Advanced 1250

Advanced 1500

Advanced 1750

Extraction

Blowing

H400

H500

F

G

F

G

F

G

1000

1004

1000

1

1

502

968

910x285

910x385

507

655

632

655

757

655

1500

1504

1500

1

1

752

1468

1410x285

1410x385

507

1265

632

1265

757

1265

2000

2004

2000

2

2

514

976

1968

1910x285

1910x385

507

1265

632

1265

757

1265

2500

2504

2500

2

2

645.5

1213

2468

2410x285

2410x385

507

1265

632

1265

757

1265

3000

3004

3000

2

2

645.5

1713

2968

2910x285

2910x385

507

1265

632

1265

757

1265

* Total length of assembled modules: 3504, 4004, 4504, 5004, 5504, 6004

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Close Open Electrical / ATEX Certificates

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

Commercial leaflet (FCOM)

OPTAIR Kitchen
Download OPTAIR Cuisine Media locked

For any questions, please send an email to optair@vim.fr

PROFESSIONAL KITCHENS
OPTAIR-Cuisine.png Calculation of flow rates
Selection of hoods and ceilings
  • Calculation of extraction, compensation and induction flow rates in the kitchen according to standard NF EN 16282-1.
  • Automatic sizing of hoods according to standard NF EN 16282-2.
  • Integrates different capture systems (standard hoods, welded hoods, UV welded hoods, filtering ceilings, capture-only hoods, inductive curtain hoods, etc.)
  • Takes into account the characteristics of the cooking appliances, the efficiency of the capture system, the fresh air diffusion method and numerous installation parameters.
  • Presents the products and systems offered by VIM in professional kitchens with links to catalog pages, specification texts and installation instructions.
VORAX COMFORT 90/10
VORAX 90/10
VORAX INDUCT/INDUCT PLUS
NOVAX CHEF
NOVAX COMFORT 90/10
NOVAX 90/10
NOVAX UV CHEF
NOVAX UV COMFORT 90/10
NOVAX UV 90/10
VORAX PREMIUM / G
VORAX CHEF / G
VORAX COMFORT
VORAX LAUNDRY / G
VORAX FOUR / G
VORAX BASIC / G
VORAX FIRST
VORAX VISION
VORAX VISION COMFORT
B'TWIN VILLAGE - LILLE

Close Open B'TWIN VILLAGE - LILLE

Shopping centers

59 - North

HOPITAL CARDIO VASCULAIRE PULMONAIRE - LILLE

Close Open HOPITAL CARDIO VASCULAIRE PULMONAIRE - LILLE

Hospitals

59 - North

MEDIATHEQUE L'AGORA - METZ

Close Open MEDIATHEQUE L'AGORA - METZ

Media library

57 - Moselle

RESTAURANT PERRUCHE - PRINTEMPS HAUSSMANN

Close Open RESTAURANT PERRUCHE - PRINTEMPS HAUSSMANN

Independent commercial catering

75 - Paris

X