Search a product :
New product
| Relay box for smoke extraction fan |
Designed for controlling a smoke extraction fan in Public Access Buildings (ERP) and High-Rise Buildings (IGH).
NF certified by AFNOR according to certification standard no. NF537 “NF Mark - Relay boxes for smoke extraction fans” in force since October 2017.
In accordance with regulations, a relay box can only control one smoke extraction fan.
Description
Dimensions
Documentation
Public Price
Software
References
|
Caliber (A) |
6 |
10.6 |
16.6 |
35.3 |
43.3 |
64 |
97.3 |
|||||||
|
Model |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
|
DP1X |
T1 |
6 |
T1 |
6 |
T1 |
7 |
T2 |
10 |
T2 |
11 |
T3 |
12 |
||
|
DP1V |
T1 |
6 |
T1 |
6 |
T3 |
8 |
T3 |
11 |
||||||
|
DP2I |
T1 |
4.5 |
T1 |
4.5 |
T1 |
5 |
T2 |
7 |
T3 |
11 |
T3 |
14 |
T5 |
16 |
|
DP2D |
T1 |
5 |
T1 |
5 |
T1 |
5.5 |
T2 |
7 |
T3 |
12 |
T4 |
14 |
T5 |
16 |
|
D1C1M |
T1 |
6.5 |
T1 |
6.5 |
||||||||||
|
D1C1MT |
T1 |
6.5 |
T1 |
6.5 |
||||||||||
|
D1C1VT |
T1 |
7 |
T1 |
7 |
T1 |
7.5 |
T2 |
12 |
T3 |
18 |
T3 |
29 |
T5 |
34 |
|
D1C2I |
T1 |
5 |
T1 |
5 |
T2 |
6 |
T3 |
17 |
T3 |
19 |
T4 |
29 |
T5 |
34 |
|
D1C2IT |
T2 |
5.5 |
T2 |
5.5 |
T2 |
7 |
T3 |
17 |
T3 |
19 |
T4 |
29 |
T5 |
34 |
|
D1C2D |
T2 |
9 |
T2 |
9 |
T2 |
9.5 |
T3 |
16 |
T3 |
18 |
T5 |
30 |
T6 |
35 |
|
D1C2DT |
T2 |
9.5 |
T2 |
9.5 |
T3 |
10 |
T3 |
16 |
T3 |
20 |
T5 |
30 |
T6 |
47 |
|
D2C2IT |
T2 |
15 |
T2 |
15 |
T3 |
15 |
T3 |
18 |
T4 |
20 |
T5 |
30 |
T6 |
49 |
|
D2C2DT |
T3 |
15 |
T3 |
15 |
T3 |
15 |
T4 |
18 |
T4 |
20 |
T5 |
30 |
T6 |
48 |
|
Caliber (A) |
16.6 |
32 |
47 |
62 |
75 |
88 |
||||||
|
Model |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
|
IDC DP1V |
T4 |
21 |
T4 |
23 |
T5 |
24 |
T5 |
25 |
T5 |
33 |
T5 |
34 |
|
IDC DP2I |
T4 |
22 |
T4 |
24 |
T5 |
30 |
T5 |
33 |
T5 |
34 |
T6 |
45 |
|
IDC D1C1V |
T4 |
22 |
T4 |
23 |
T5 |
30 |
T5 |
33 |
T5 |
34 |
T6 |
46 |
|
IDC D1C1VT |
T4 |
22 |
T4 |
23 |
T5 |
31 |
T5 |
34 |
T5 |
35 |
T6 |
46 |
|
IDC D1C2I |
T4 |
23 |
T5 |
30 |
T5 |
32 |
T6 |
44 |
T6 |
45 |
T6 |
46 |
|
IDC D1C2IT |
T4 |
23 |
T4 |
24 |
T5 |
33 |
T5 |
34 |
T5 |
35 |
T6 |
46 |
|
IDC D2C2IT |
T4 |
23 |
T5 |
32 |
T5 |
34 |
T5 |
35 |
T6 |
46 |
T6 |
47 |
|
Caliber (A) |
110 |
170 |
203.3 |
246.6 |
305 |
|||||
|
Model |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
T |
Kg |
|
IDC DP1V |
T6 |
45 |
T7 |
54 |
T8 |
69 |
T9 |
82 |
T9 |
89 |
|
IDC DP2I |
T6 |
46 |
T7 |
57 |
T9 |
75 |
T9 |
85 |
T10 |
98 |
|
IDC D1C1V |
T6 |
47 |
||||||||
|
IDC D1C1VT |
T6 |
47 |
||||||||
|
IDC D1C2I |
T7 |
55 |
||||||||
|
IDC D1C2IT |
T6 |
47 |
||||||||
|
IDC D2C2IT |
T7 |
58 |
||||||||

(1) When the isolator is integrated, add 35 mm.
* Fixing ribs
|
Size |
Overall (mm) |
Fasteners (mm) |
|||||
|
Long. |
H |
P (1) |
f1 |
h1 |
f2 |
h2 |
|
|
T1 |
380 |
254 |
165 |
371 |
239 |
346 |
264 |

(1) With the fixing brackets, add 14 mm. When the switch is integrated, add 35 mm.
* Fixing ribs
|
Size |
Overall (mm) |
||
|
L |
H |
P (1) |
|
|
T2 |
400 |
300 |
200 |
|
T3 |
500 |
400 |
200 |
|
T4 |
600 |
400 |
250 |
|
T5 |
700 |
500 |
250 |
|
T6 |
800 |
600 |
300 |
|
T7 |
1000 |
600 |
300 |
|
T8 |
1000 |
800 |
400 |
|
T9 |
800 |
1200 |
400 |
|
T10 |
1000 |
1200 |
400 |
Detailed specifications
Text catalog pages (CT)
Public tariff price
Price catalog pages (CP)
Installation instructions
Installation instructions (NT)
Installation instructions (NT) Other
Installation instructions (NT) Other languages
Performance / Environment Certificates
NF certificate (CNF)
Electrical / ATEX Certificates
Electrical CE Declarations (DCCE)
Prescription assistance
Commercial documents
Commercial leaflet (FCOM)
Detailed specifications
Text catalog pages (CT)
Public tariff price
Price catalog pages (CP)
Installation instructions
Installation instructions (NT)
Installation instructions (NT) Other
Installation instructions (NT) Other languages
Performance / Environment Certificates
NF certificate (CNF)
Electrical / ATEX Certificates
Electrical CE Declarations (DCCE)
Prescription assistance
Commercial documents
Commercial leaflet (FCOM)
AEROPORT TERMINAL 1 - SAINT EXUPERY - LYON
Airports
69 - Rhône
Installed products:
BASE LOGISTIQUE INTERMARCHE
Shipping or storage
56 - Morbihan
Installed products:
BIOTOPE - METROPOLE EUROPEENNE LILLE
Administrations
59 - North
Installed products:
CLUB MED ALPES D'HUEZ
Hotel residences
38 - Isère
Installed products:
COMPLEXE PIERRES VIVES - MONTPELLIER
Media library
34 - Herault
Installed products:
ECOLE ROCKEFELLER
Specialized education
69 - Rhône
Installed products:
EHPAD - LA QUEUE EN BRIE
Residences for the elderly
94 - Val-de-Marne
Installed products:
EHPAD PIERRE MEUNIER - LA FOUILLOUSE
Residences for the elderly
42 - Loire
Installed products:
GRAND STADE - LILLE
Stadiums
59 - North
Installed products:
GRANDE HALLE D'AUVERGNE - COURNON
Performance halls
63 - Puy-de-Dome
Installed products:
HOTEL ROYAL HAINAUT - VALENCIENNES
Hotels
59 - North
Installed products:
PARKING HOTEL DE VILLE - POITIERS
Tertiary car parks
86 - Vienna
Installed products:
PORTE ROMAINE - NIMES
Private collective housing
30 - Gard
Installed products:
VILL UP - LA VILLETTE - PARIS
Shopping centers
75 - Paris
Installed products: